Description
First thanks for a great tool.
This is a real trivial request: could the output for CH CL be
switched in these (and any other displays).
And could the SN be positioned to the right of DH
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 70 31 a1 40 00 04:08:14.561 READ DMA EXT
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 70 31 a1 43 Error: UNC 8 sectors at LBA = 0x03a13170 = 60895600
Change History (2)
comment:1 Changed 12 years ago by
Keywords: | ata added |
---|
comment:2 Changed 12 years ago by
Resolution: | → wontfix |
---|---|
Status: | new → closed |
Note: See
TracTickets for help on using
tickets.
Changing this old log output might break external tools parsing it.
Please note that the old Summary SMART error log is now outdated because it does not support LBA-48 ATA commands. Use Extended Comprehensive SMART error log if possible ( (
smartctl -l xerror ...
).