#668 fixed Add new Apple SSD to drive database beren
Description

The new Apple SSDs seem to have the same odd values. Someone added 173 as Wear_Leveling_Count which doesn't seem right to me. I added the G model to my local copy.

=== START OF INFORMATION SECTION ===
Model Family:     Apple SD/SM/TS...E/F SSDs
Device Model:     APPLE SSD SM0512G
Firmware Version: BXW1SA0Q
User Capacity:    500,277,790,720 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Mon Mar 14 12:13:03 2016 EDT


ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x001a   200   200   000    Old_age   Always       -       0
  5 Reallocated_Sector_Ct   0x0033   100   100   000    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       1060
 12 Power_Cycle_Count       0x0032   094   094   000    Old_age   Always       -       5651
169 Unknown_Attribute       0x0013   221   221   010    Pre-fail  Always       -       4222129014656
173 Wear_Leveling_Count     0x0032   198   198   100    Old_age   Always       -       30069096468
174 Host_Reads_MiB          0x0022   099   099   000    Old_age   Always       -       7219227
175 Host_Writes_MiB         0x0022   099   099   000    Old_age   Always       -       8097664
192 Power-Off_Retract_Count 0x0012   099   099   000    Old_age   Always       -       67
194 Temperature_Celsius     0x0022   077   019   000    Old_age   Always       -       23 (Min/Max 14/83)
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0
199 UDMA_CRC_Error_Count    0x001a   200   200   000    Old_age   Always       -       0

#672 fixed SG9XCS2D50GE01 missing from SmartDB J Wass
Description

Hi Team,

I have provided the output of: smartctl -x /dev/sdX > smartctl-VENDOR-MODEL.txt

For the disk: Vendor:SMART Modular Technology Model:SG9XCS2D50GE01

Regards

#673 fixed Add to database - KINGSTON SKC400S37128G (SSDNow KC400) The_Ball
Description

The SMART attributes are specified in this PDF: http://media.kingston.com/support/downloads/MKP_521_Phison_SMART_attribute.pdf

Attribute 231 "SSD Life Left" 0-100% would be very good to have defined in the db.

Batch Modify
Note: See TracBatchModify for help on using batch modify.