Ticket #704: smartctl-SAMSUNG-MZHPV512HDGL-00000.txt

File smartctl-SAMSUNG-MZHPV512HDGL-00000.txt, 8.6 KB (added by Konrad J Hambrick, 3 years ago)

smartctl -x /dev/sdc for SAMSUNG MZHPV512HDGL-00000

Line 
1smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.4.12] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model:     SAMSUNG MZHPV512HDGL-00000
6Serial Number:    S1X1NYAG614548
7LU WWN Device Id: 5 002538 900021fb1
8Firmware Version: BXW2500Q
9User Capacity:    512,110,190,592 bytes [512 GB]
10Sector Size:      512 bytes logical/physical
11Rotation Rate:    Solid State Device
12Device is:        Not in smartctl database [for details use: -P showall]
13ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
14SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
15Local Time is:    Tue Jun  7 05:59:33 2016 CDT
16SMART support is: Available - device has SMART capability.
17SMART support is: Enabled
18AAM feature is:   Unavailable
19APM feature is:   Unavailable
20Rd look-ahead is: Enabled
21Write cache is:   Enabled
22ATA Security is:  Disabled, frozen [SEC2]
23Wt Cache Reorder: Enabled
24
25=== START OF READ SMART DATA SECTION ===
26SMART overall-health self-assessment test result: PASSED
27
28General SMART Values:
29Offline data collection status:  (0x00) Offline data collection activity
30                                        was never started.
31                                        Auto Offline Data Collection: Disabled.
32Self-test execution status:      (   0) The previous self-test routine completed
33                                        without error or no self-test has ever
34                                        been run.
35Total time to complete Offline
36data collection:                (    0) seconds.
37Offline data collection
38capabilities:                    (0x53) SMART execute Offline immediate.
39                                        Auto Offline data collection on/off support.
40                                        Suspend Offline collection upon new
41                                        command.
42                                        No Offline surface scan supported.
43                                        Self-test supported.
44                                        No Conveyance Self-test supported.
45                                        Selective Self-test supported.
46SMART capabilities:            (0x0003) Saves SMART data before entering
47                                        power-saving mode.
48                                        Supports SMART auto save timer.
49Error logging capability:        (0x01) Error logging supported.
50                                        General Purpose Logging supported.
51Short self-test routine
52recommended polling time:        (   2) minutes.
53Extended self-test routine
54recommended polling time:        (  35) minutes.
55SCT capabilities:              (0x003d) SCT Status supported.
56                                        SCT Error Recovery Control supported.
57                                        SCT Feature Control supported.
58                                        SCT Data Table supported.
59
60SMART Attributes Data Structure revision number: 1
61Vendor Specific SMART Attributes with Thresholds:
62ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
63  5 Reallocated_Sector_Ct   PO--CK   100   100   010    -    0
64  9 Power_On_Hours          -O--CK   099   099   000    -    4454
65 12 Power_Cycle_Count       -O--CK   099   099   000    -    98
66170 Unknown_Attribute       -O--CK   100   100   010    -    0
67171 Unknown_Attribute       -O--CK   100   100   010    -    0
68172 Unknown_Attribute       -O--CK   100   100   010    -    0
69173 Unknown_Attribute       PO--CK   100   100   005    -    0
70174 Unknown_Attribute       -O--CK   099   099   000    -    29
71178 Used_Rsvd_Blk_Cnt_Chip  PO--C-   100   100   010    -    0
72180 Unused_Rsvd_Blk_Cnt_Tot PO--C-   100   100   010    -    1634
73184 End-to-End_Error        PO--CK   100   100   097    -    0
74187 Reported_Uncorrect      -O--CK   100   100   000    -    0
75194 Temperature_Celsius     -O--CK   051   035   000    -    49
76199 UDMA_CRC_Error_Count    -OSRCK   100   100   000    -    0
77233 Media_Wearout_Indicator -O--CK   099   099   000    -    201
78241 Total_LBAs_Written      -O--CK   099   099   000    -    201
79242 Total_LBAs_Read         -O--CK   099   099   000    -    203
80                            ||||||_ K auto-keep
81                            |||||__ C event count
82                            ||||___ R error rate
83                            |||____ S speed/performance
84                            ||_____ O updated online
85                            |______ P prefailure warning
86
87General Purpose Log Directory Version 1
88SMART           Log Directory Version 1 [multi-sector log support]
89Address    Access  R/W   Size  Description
900x00       GPL,SL  R/O      1  Log Directory
910x01           SL  R/O      1  Summary SMART error log
920x02           SL  R/O      1  Comprehensive SMART error log
930x03       GPL     R/O      1  Ext. Comprehensive SMART error log
940x06           SL  R/O      1  SMART self-test log
950x07       GPL     R/O      1  Extended self-test log
960x09           SL  R/W      1  Selective self-test log
970x10       GPL     R/O      1  SATA NCQ Queued Error log
980x11       GPL     R/O      1  SATA Phy Event Counters log
990x13       GPL     R/O      1  SATA NCQ Send and Receive log
1000x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
1010x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
1020xdf       GPL     VS       1  Device vendor specific log
103
104SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
105No Errors Logged
106
107SMART Extended Self-test Log Version: 1 (1 sectors)
108Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
109# 1  Short offline       Completed without error       00%      4454         -
110# 2  Short offline       Completed without error       00%      4453         -
111# 3  Short offline       Completed without error       00%      4453         -
112
113SMART Selective self-test log data structure revision number 1
114 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
115    1        0        0  Not_testing
116    2        0        0  Not_testing
117    3        0        0  Not_testing
118    4        0        0  Not_testing
119    5        0        0  Not_testing
120  255        0    65535  Read_scanning was never started
121Selective self-test flags (0x0):
122  After scanning selected spans, do NOT read-scan remainder of disk.
123If Selective self-test is pending on power-up, resume after 0 minute delay.
124
125SCT Status Version:                  3
126SCT Version (vendor specific):       256 (0x0100)
127SCT Support Level:                   1
128Device State:                        SCT command executing in background (5)
129Current Temperature:                    50 Celsius
130Power Cycle Min/Max Temperature:     40/52 Celsius
131Lifetime    Min/Max Temperature:      0/70 Celsius
132Under/Over Temperature Limit Count:  4294967295/4294901760
133SMART Status:                        0xffff (Reserved)
134
135SCT Temperature History Version:     3 (Unknown, should be 2)
136Temperature Sampling Period:         1 minute
137Temperature Logging Interval:        10 minutes
138Min/Max recommended Temperature:      0/70 Celsius
139Min/Max Temperature Limit:            0/70 Celsius
140Temperature History Size (Index):    128 (49)
141
142Index    Estimated Time   Temperature Celsius
143  50    2016-06-06 08:40    48  *****************************
144 ...    ..( 13 skipped).    ..  *****************************
145  64    2016-06-06 11:00    48  *****************************
146  65    2016-06-06 11:10    49  ******************************
147 ...    ..( 13 skipped).    ..  ******************************
148  79    2016-06-06 13:30    49  ******************************
149  80    2016-06-06 13:40    50  *******************************
150 ...    ..( 13 skipped).    ..  *******************************
151  94    2016-06-06 16:00    50  *******************************
152  95    2016-06-06 16:10    51  ********************************
153 ...    ..( 12 skipped).    ..  ********************************
154 108    2016-06-06 18:20    51  ********************************
155 109    2016-06-06 18:30    52  *********************************
156 ...    ..( 12 skipped).    ..  *********************************
157 122    2016-06-06 20:40    52  *********************************
158 123    2016-06-06 20:50    51  ********************************
159 124    2016-06-06 21:00    51  ********************************
160 125    2016-06-06 21:10    52  *********************************
161 ...    ..( 13 skipped).    ..  *********************************
162  11    2016-06-06 23:30    52  *********************************
163  12    2016-06-06 23:40    51  ********************************
164 ...    ..( 19 skipped).    ..  ********************************
165  32    2016-06-07 03:00    51  ********************************
166  33    2016-06-07 03:10    50  *******************************
167 ...    ..(  9 skipped).    ..  *******************************
168  43    2016-06-07 04:50    50  *******************************
169  44    2016-06-07 05:00    49  ******************************
170 ...    ..(  3 skipped).    ..  ******************************
171  48    2016-06-07 05:40    49  ******************************
172  49    2016-06-07 05:50    50  *******************************
173
174SCT Error Recovery Control:
175           Read: Disabled
176          Write: Disabled
177
178Device Statistics (GP/SMART Log 0x04) not supported
179
180SATA Phy Event Counters (GP Log 0x11)
181ID      Size     Value  Description
1820x0001  4            0  Command failed due to ICRC error
1830x000a  4           16  Device-to-host register FISes sent due to a COMRESET
184