Ticket #1752: smartctl_result_TS512GSSD470K.txt

File smartctl_result_TS512GSSD470K.txt, 5.5 KB (added by keigo_nakamura, 7 months ago)

smartctl report

Line 
1smartctl 7.0 2018-12-30 r4883 [x86_64-linux-3.10.0-1127.8.2.el7.x86_64] (local build)
2Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: TS512GSSD470K
6Serial Number: H805960079
7LU WWN Device Id: 5 7c3548 20ce0498f
8Firmware Version: 22Z2UCFS
9User Capacity: 512,110,190,592 bytes [512 GB]
10Sector Size: 512 bytes logical/physical
11Rotation Rate: Solid State Device
12Form Factor: 2.5 inches
13Device is: Not in smartctl database [for details use: -P showall]
14ATA Version is: ACS-3 T13/2161-D revision 5
15SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
16Local Time is: Tue Oct 3 18:38:28 2023 JST
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19
20=== START OF READ SMART DATA SECTION ===
21SMART overall-health self-assessment test result: PASSED
22
23General SMART Values:
24Offline data collection status: (0x00) Offline data collection activity
25 was never started.
26 Auto Offline Data Collection: Disabled.
27Self-test execution status: ( 0) The previous self-test routine completed
28 without error or no self-test has ever
29 been run.
30Total time to complete Offline
31data collection: ( 0) seconds.
32Offline data collection
33capabilities: (0x7b) SMART execute Offline immediate.
34 Auto Offline data collection on/off support.
35 Suspend Offline collection upon new
36 command.
37 Offline surface scan supported.
38 Self-test supported.
39 Conveyance Self-test supported.
40 Selective Self-test supported.
41SMART capabilities: (0x0002) Does not save SMART data before
42 entering power-saving mode.
43 Supports SMART auto save timer.
44Error logging capability: (0x01) Error logging supported.
45 General Purpose Logging supported.
46Short self-test routine
47recommended polling time: ( 2) minutes.
48Extended self-test routine
49recommended polling time: ( 30) minutes.
50Conveyance self-test routine
51recommended polling time: ( 2) minutes.
52
53SMART Attributes Data Structure revision number: 16
54Vendor Specific SMART Attributes with Thresholds:
55ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
56 1 Raw_Read_Error_Rate 0x0000 100 100 000 Old_age Offline - 0
57 5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline - 0
58 9 Power_On_Hours 0x0000 100 100 000 Old_age Offline - 435
59 12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline - 10
60148 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 76
61149 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 2
62150 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
63151 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
64159 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
65160 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
66161 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 55
67163 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 66
68164 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 3
69165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 1
70166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
71167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
72168 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 3000
73169 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 100
74177 Wear_Leveling_Count 0x0000 100 100 050 Old_age Offline - 0
75181 Program_Fail_Cnt_Total 0x0000 100 100 000 Old_age Offline - 0
76182 Erase_Fail_Count_Total 0x0000 100 100 000 Old_age Offline - 0
77192 Power-Off_Retract_Count 0x0000 100 100 000 Old_age Offline - 4
78194 Temperature_Celsius 0x0000 100 100 000 Old_age Offline - 42
79195 Hardware_ECC_Recovered 0x0000 100 100 000 Old_age Offline - 0
80196 Reallocated_Event_Count 0x0000 100 100 016 Old_age Offline - 0
81199 UDMA_CRC_Error_Count 0x0000 100 100 050 Old_age Offline - 1
82232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline - 100
83241 Total_LBAs_Written 0x0000 100 100 000 Old_age Offline - 144
84242 Total_LBAs_Read 0x0000 100 100 000 Old_age Offline - 1
85245 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 31
86
87SMART Error Log Version: 1
88No Errors Logged
89
90SMART Self-test log structure revision number 1
91No self-tests have been logged. [To run self-tests, use: smartctl -t]
92
93SMART Selective self-test log data structure revision number 1
94 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
95 1 0 0 Not_testing
96 2 0 0 Not_testing
97 3 0 0 Not_testing
98 4 0 0 Not_testing
99 5 0 0 Completed [00% left] (0-65535)
100Selective self-test flags (0x0):
101 After scanning selected spans, do NOT read-scan remainder of disk.
102If Selective self-test is pending on power-up, resume after 0 minute delay.
103