Timeline



04/13/2018:

06:52 Ticket #1024 (Crucial CT250MX500SSD1) closed by Christian Franke
duplicate: See ticket #977.

04/12/2018:

16:44 Ticket #1024 (Crucial CT250MX500SSD1) created by JetStream
Details for Crucial MX500 (240GB), not found in the trunk drivedb.h. …

04/10/2018:

13:34 Ticket #1023 (drive database: Toshiba MG06ACA10TE and MG07ACA14TE) created by Dmitry Nosachev
[https://toshiba.semicon-storage.com/ap-en/product/storage-products/ent

04/04/2018:

03:55 Ticket #1022 (Micron_5200_MTFDDAK1T9TDC) created by Artem Likhachev
https://www.micron.com/products/solid-state-storage/product-lines/5200
03:42 Ticket #1021 (SanDisk SD6SP1M128G1102) created by Artem Likhachev
This drive is used in Asus UX31L (production of 2013 year). Here is …

04/03/2018:

19:29 Ticket #1017 (make smartd usable as temperature monitor / replace hddtemp) closed by Christian Franke
duplicate: For 1), see ticket #1018. For 2) and 3), please create separate tickets.
13:20 Supported_USB-Devices edited by ghalfacree
Added WD Pi Drive (diff)

03/28/2018:

20:55 Changeset [4726] by Christian Franke
ataprint.cpp, nvmeprint.cpp, scsiprint.cpp: Output JSON …
19:55 Changeset [4725] by Christian Franke
smartd.cpp: Ignore remaining percentage in initial check of self-test …
19:44 Changeset [4724] by Christian Franke
scsiata.cpp: Fix device type info for 'usbcypress'.
19:37 Changeset [4723] by Christian Franke
os_linux.cpp: Fix device scan crash on missing /proc/devices.
19:30 Changeset [4722] by Christian Franke
update-smart-drivedb.in, update-smart-drivedb.8.in: Add option '-u github'.
10:25 Ticket #1014 (smartd doesn't notice newly added devices afters start) closed by Christian Franke
duplicate: See ticket #60.
10:24 Ticket #218 (DEVICESCAN -d removable) closed by Christian Franke
duplicate: See ticket #60.
08:53 Ticket #1019 (allow for shorter check intervals (and perhaps use them per default)) closed by Christian Franke
invalid: The minimum check interval is 10 seconds (´-i 10´). See smartd …
08:06 Ticket #1016 (let smartd check a device (to be monitored) shortly after it's attached) closed by Christian Franke
duplicate: See ticket #1014.
08:01 Ticket #1015 (smartd double monitors devices when using symlinks to devices) closed by Christian Franke
duplicate: This is already fixed since r4556, see ticket #313. If the problem …
02:40 Ticket #1020 (SanDisk SD8SN8U512G1002) created by jdiazgonz
[…]

03/27/2018:

14:54 Ticket #1019 (allow for shorter check intervals (and perhaps use them per default)) created by calestyo
Hi. The minimum check interval for smartd seems to be 10 minutes and …
14:48 Ticket #1018 (allow for constant re-sending of warnings) created by calestyo
Hi. This kinda overlaps with #1017. Right now, AFAIU, smartd will …
14:42 Ticket #1017 (make smartd usable as temperature monitor / replace hddtemp) created by calestyo
Hi. It seems to me that hddtemp, is more or less dead and …
14:06 Ticket #1016 (let smartd check a device (to be monitored) shortly after it's attached) created by calestyo
Hi. This is kinda related to #1014... When a removable device (e.g. …
13:57 Ticket #1015 (smartd double monitors devices when using symlinks to devices) created by calestyo
Forwarded from: …
13:53 Ticket #1014 (smartd doesn't notice newly added devices afters start) created by calestyo
Forwarded from: …
13:44 Ticket #1013 (-M exec overrides -M <others>) created by calestyo
Forwarded from: …

03/26/2018:

19:48 Ticket #1012 (Please add Western Digital WD6001F4PZ-49CWHM0 to the database) created by Cmdr_Zod
This drive belongs the "Ae" cold storage class. Please find attached …

03/23/2018:

08:14 Ticket #933 (add to drivedb: KINGSTON SEDC400S37960G Solid State Device 960 GB) closed by Christian Franke
duplicate: See ticket #1011.

03/22/2018:

08:07 Ticket #1011 (smartctl-KINGSTON-SEDC400S37480G.txt) created by Ivan Bobrov
[http://media.kingston.com/support/downloads/MKP_521_Phison_SMART_attri

03/21/2018:

01:07 Ticket #1010 (add to drivedb: Samsung SSD 860 PRO) created by toppk

03/20/2018:

22:29 Changeset [4721] by Christian Franke
nvmeprint.cpp: Add initial JSON support for '-i', '-H' and '-A'.
22:20 Changeset [4720] by Christian Franke
json.cpp, json.h: Add support for 64 and 128 bit unsigned integers. …

03/16/2018:

09:40 Ticket #1009 (Please add to the Smartmontools Database) closed by Christian Franke
wontfix: This is not a physical HDD or SSD. It is a logical drive emulated by …

03/15/2018:

16:09 Ticket #1009 (Please add to the Smartmontools Database) created by erikire
Hi, could you please add the drive for the MARVELL Raid VD to the …

03/14/2018:

12:03 Ticket #1002 (add to drivedb: Western Digital USB ID (1058:1078)) closed by Christian Franke
worksforme: USB Vendor ID 0x1058 now defaults to -d sat, see r4687, r4692. …
11:53 Ticket #1004 (add to drivedb: CT2000MX500SSD1) closed by Christian Franke
duplicate: See ticket #977.
11:52 Ticket #995 (add to drivedb: CT500MX500SSD1) closed by Christian Franke
duplicate: See ticket #977.
11:50 Ticket #994 (add to drivedb: CT1000MX500SSD1) closed by Christian Franke
duplicate: See ticket #977.
08:54 Ticket #1008 (JMicron 152d:0539 always run smart check only over the first disk) closed by Christian Franke
invalid: This is a bug in the JMicron USB bridge firmware and cannot be fixed …
00:48 Ticket #1008 (JMicron 152d:0539 always run smart check only over the first disk) created by Daniele Palumbo
I have bought quite time ago a Orico B01823CC8Y, 4 bay open tray. -d …
Note: See TracTimeline for information about the timeline view.