Opened 6 years ago

Closed 3 years ago

#973 closed enhancement (worksforme)

Please add Seagate Expansion Portable Drive SRD0NF1 1TEAP5-500

Reported by: pgkos Owned by:
Priority: minor Milestone: Release 7.1
Component: drivedb Version: 6.6
Keywords: hdd Cc:

Description

This is an external 1TB USB 3.0 drive.

Information from the label on the bottom of the drive:

Seagate Expansion Portable Drive
Model: SRD0NF1
PN: 1TEAP5-500

UASP has to be disabled for this drive on Linux, else SMART parameters cannot be read from the drive (scsi error unsupported field in scsi command).

Please find attached the output of smartctl -q noserial -x /dev/sdX

Attachments (2)

smartctl-0bc2-2322.txt (11.2 KB) - added by pgkos 6 years ago.
smartctl-Seagate-ST1000LM035.txt (13.8 KB) - added by Gabriele Pohl 5 years ago.
Another report for ST1000LM035-1RK172, here with firmware version LCM2 (sent via database ML: https://listi.jpberlin.de/pipermail/smartmontools-database/2018-March/000164.html)

Download all attachments as: .zip

Change History (7)

Changed 6 years ago by pgkos

Attachment: smartctl-0bc2-2322.txt added

comment:1 Changed 6 years ago by pgkos

Vendor ID: 0bc2
Device ID: 2322

comment:2 Changed 6 years ago by Christian Franke

Milestone: unscheduled

Problem with UAS was also reported for similar drive with Id 0x0bc2:0x231a, see ticket #971.

USB Id 0x0bc2:0x2322 is already in drivedb, SATA identity ST1000LM035-1RK172 is not.

comment:3 Changed 6 years ago by pgkos

Yes, since kernel 4.14 all Seagate enclosures have ATA passthrough disabled when using UAS (https://github.com/torvalds/linux/commit/7fee72d5e8f1e7b8d8212e28291b1a0243ecf2f1).

Changed 5 years ago by Gabriele Pohl

Another report for ST1000LM035-1RK172, here with firmware version LCM2 (sent via database ML: https://listi.jpberlin.de/pipermail/smartmontools-database/2018-March/000164.html)

comment:4 Changed 5 years ago by Christian Franke

Keywords: hdd added

comment:5 Changed 3 years ago by Christian Franke

Milestone: unscheduledRelease 7.1
Resolution: worksforme
Status: newclosed

Already added in r4988, r4998 and included in smartmontools release 7.1

Note: See TracTickets for help on using tickets.