Opened 13 years ago
Closed 13 years ago
#85 closed enhancement (fixed)
Enhance drivedb for SAMSUNG SV1604N
Reported by: | tobthea | Owned by: | Christian Franke |
---|---|---|---|
Priority: | major | Milestone: | Release 5.40 |
Component: | smartctl | Version: | |
Keywords: | Cc: |
Description
I have got a SAMSUNG SV1604N with firmware version TR100-23.
After some research on the web I found out that I need to manually append -v 9,halfminutes -F samsung2 in order to get a correct output from smartctl.
-v 9,halfminutes is needed otherwise Power on Hours is insanely high (~750000 hours)
-F samsung2 is needed - otherwise I get an extra warning: "Warning: ATA error count xxx inconsistent with error log pointer 5"
Please add this information to your drive db so that everybody will get the correct values by default.
Thanks
Attachments (2)
Change History (6)
comment:1 follow-up: 2 Changed 13 years ago by
Changed 13 years ago by
Attachment: | withoptions added |
---|
smartctl -a -v 9,halfminutes -F samsung2 output
comment:3 Changed 13 years ago by
Owner: | changed from somebody to Christian Franke |
---|---|
Status: | new → accepted |
Type: | defect → enhancement |
Note: See
TracTickets for help on using
tickets.
Please attach 'smartctl -a' output.