id summary reporter owner description type status priority milestone component version resolution keywords cc 793 SMART error (FailedReadSmartSelfTestLog) detected on host: xxx valisann "Hi, I need your help regarding an issue related with smartmontools apps. I have a linux server (Debian GNU/Linux 8 (jessie), installed on a Supermicro 2U 6027R-E1R12L with a raid controller LSI. {{{ root@pm03:~# lspci | egrep -i 'raid|adaptec' 03:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05) }}} On LSI I have 2 raid configuration: Raid 1 - 2 SSD - Intel SSD DC S3500 Series 120GB Raid 10 - 7 HDD (6 + 1 spare) - Seagate Constellation ES.3 3.5'' 2TB SAS {{{ root@pm03:~#_ smartctl --scan /dev/sda_ -d scsi # /dev/sda, SCSI device /dev/sdb_ -d scsi # /dev/sdb, SCSI device /dev/bus/0_ -d megaraid,0 # /dev/bus/0 [megaraid_disk_00], SCSI device /dev/bus/0_ -d megaraid,1 # /dev/bus/0 [megaraid_disk_01], SCSI device /dev/bus/0_ -d megaraid,2 # /dev/bus/0 [megaraid_disk_02], SCSI device /dev/bus/0_ -d megaraid,3 # /dev/bus/0 [megaraid_disk_03], SCSI device /dev/bus/0_ -d megaraid,4 # /dev/bus/0 [megaraid_disk_04], SCSI device /dev/bus/0__ -d megaraid,5 # /dev/bus/0 [megaraid_disk_05], SCSI device /dev/bus/0_ -d megaraid,6 # /dev/bus/0 [megaraid_disk_06], SCSI device /dev/bus/0_ -d megaraid,7 # /dev/bus/0 [megaraid_disk_07], SCSI device /dev/bus/0 -d megaraid,15 # /dev/bus/0 [megaraid_disk_15], SCSI device spare }}} '''issue - I have received an error log ""SMART error (FailedReadSmartSelfTestLog) detected on host: xxx"" (see the message logs).''' - this was a spare disk form RAID 10 with ID 08 {{{ This message was generated by the smartd daemon running on: host name: XXXX DNS domain: mydomain.int The following warning/error was logged by the smartd daemon: Device: /dev/bus/0 [megaraid_disk_08], Read SMART Self-Test Log Failed Device_ info: [SEAGATE ST2000NM0023 0004], lu id: 0x5000c500628f5dcf, S/N: Z1Y2C8G90000C5124838, 2.00 TB For details see host's SYSLOG. You can also use the smartctl utility for further investigation. Another message will be sent in 24 hours if the problem persists._ }}} - I have contact the vendor and I have change the disk...after that, the SMART test on the new disk (with ID 15), was OK - after 1 day the error is Back :( {{{ This message was generated by the smartd daemon running on: host name: pm03 DNS domain: mercury.int The following warning/error was logged by the smartd daemon: Device: /dev/bus/0 [megaraid_disk_15], Read SMART Self-Test Log Failed Device info: [SEAGATE ST2000NM0023 0004], lu id: 0x5000c500845a1abf, S/N: Z1X5VF2R0000C6095M9C, 2.00 TB For details see host's SYSLOG. You can also use the smartctl utility for further investigation. Another message will be sent in 24 hours if the problem persists. }}} Another problem that I noticed after I have detect is that I cannot see in -- Disk information -- about the spare disk, using the command megaclisas-status && megasasctl before https://drive.google.com/open?id=0B5sUwIIchHUgUlA4UGwyZTZaSjQ [[Image(https://drive.google.com/open?id=0B5sUwIIchHUgUlA4UGwyZTZaSjQ)]] after https://drive.google.com/open?id=0B5sUwIIchHUgMXBDRzExaXhZOE0 [[Image(https://drive.google.com/open?id=0B5sUwIIchHUgMXBDRzExaXhZOE0)]] - the rest of the disks form RAID10, don't have issues on SMART - other log, if helps {{{ root@pm03:~# smartctl -a /dev/bus/0 -d megaraid,15 smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.4.35-1-pve] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: SEAGATE Product: ST2000NM0023 Revision: 0004 Compliance: SPC-4 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Logical block size: 512 bytes LU is fully provisioned Rotation Rate: 7200 rpm Form Factor: 3.5 inches Logical Unit id: 0x5000c500845a1abf Serial number: Z1X5VF2R0000C6095M9C Device type: disk Transport protocol: SAS (SPL-3) Local Time is: Fri Jan 13 13:54:06 2017 EET SMART support is: Unavailable - device lacks SMART capability. === START OF READ SMART DATA SECTION === Current Drive Temperature: 0 C Drive Trip Temperature: 0 C Error Counter logging not supported Device does not support Self Test logging }}} megacli 8.07.14-1 amd64 LSI Logic MegaRAID SAS MegaCLI megaclisas-status 0.15 all get RAID status out of LSI MegaRAID SAS HW RAID controllers megactl 0.4.1+svn20090725.r6-5 amd64 LSI MegaRAID SCSI/SAS reporting tool megaraid-status 0.12 all get RAID status out of LSI MegaRAID SCSI/SAS HW RAID controllers Thanks" defect closed major all 6.5 invalid megaraid linux scsi