Changes between Initial Version and Version 1 of Ticket #788


Ignore:
Timestamp:
Jan 4, 2017, 10:07:33 AM (7 years ago)
Author:
Christian Franke
Comment:

Legend:

Unmodified
Added
Removed
Modified
  • Ticket #788 – Description

    initial v1  
    22
    33syslog entries like
    4 
     4{{{
    55Jan 2 20:22:27 server smartd[876]: Device: /dev/sda [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 110 to 112
    6 
     6}}}
    77should be less confusing and logging should by default only take place if something is worth to be warned about.
    88
     
    1010
    1111And the output could be more verbose and less confusing. I suggest:
    12 
     12{{{
    1313Jan 2 20:22:27 server smartd[876]: Device: /dev/sda [SAT], SMART Usage Attribute: 194 Temperature_Celsius: Thermal health changed from 110% (40°C) to 112% (38°C)
    14 
     14}}}
    1515Given that normalization is specified by vendors, smartmontools could also take into account that e.g. health below 90% is critical (for WD drives that would be 60°C) and also should reported as critical (WARNING, etc.).