Opened 8 years ago

Closed 7 years ago

Last modified 7 years ago

#713 closed enhancement (fixed)

Add Innodisk Mini PCIeDOM 1ME3 to the drive database

Reported by: manrud Owned by: Christian Franke
Priority: minor Milestone: Release 6.6
Component: drivedb Version: 6.5
Keywords: Cc:

Description

smartctl 6.5 2016-05-07 r4318 [ppc-linux-3.2.78-rt113] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     Mini PCIeDOM 1ME3
Serial Number:    20151006AA1858000001
LU WWN Device Id: 5 24693e 2015a0001
Firmware Version: S15604
User Capacity:    64,023,257,088 bytes [64.0 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 3.0, 1.5 Gb/s (current: 1.5 Gb/s)
Local Time is:    Mon Jan  3 19:25:53 2000 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Read SCT Status failed: scsi error aborted command
Wt Cache Reorder: Unknown (SCT Feature Control command failed)

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection:                (   32) seconds.
Offline data collection
capabilities:                    (0x0b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        No Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.
SCT capabilities:              (0x0039) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   000   000   000    -    0
  2 Throughput_Performance  ------   000   000   000    -    0
  3 Spin_Up_Time            ------   000   000   000    -    0
  5 Reallocated_Sector_Ct   -O----   100   100   000    -    0
  7 Unknown_SSD_Attribute   ------   000   000   000    -    0
  8 Unknown_SSD_Attribute   ------   000   000   000    -    0
  9 Power_On_Hours          -O----   100   100   000    -    18
 10 Unknown_SSD_Attribute   ------   000   000   000    -    0
 12 Power_Cycle_Count       -O----   100   100   000    -    33
168 Unknown_Attribute       ------   000   000   000    -    0
169 Unknown_Attribute       ------   099   000   000    -    108851651149824
175 Program_Fail_Count_Chip ------   000   000   000    -    0
192 Power-Off_Retract_Count ------   000   000   000    -    0
194 Temperature_Celsius     ------   030   100   000    -    0 (2 100 0 0 0)
197 Current_Pending_Sector  ------   000   000   000    -    0
240 Unknown_SSD_Attribute   ------   000   182   000    -    335698
225 Unknown_SSD_Attribute   ------   000   000   000    -    0
170 Unknown_Attribute       PO----   000   000   ---    -    2228224
173 Unknown_Attribute       -O--C-   000   000   ---    -    196609
229 Unknown_Attribute       -O----   000   000   ---    -    88470212370072
236 Unknown_Attribute       -O----   000   000   ---    -    0
235 Unknown_Attribute       -O----   000   000   ---    -    0
176 Erase_Fail_Count_Chip   ------   000   000   ---    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed: scsi error aborted command

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error aborted command
Read GP Log Directory failed

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log not supported

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test Log not supported

Selective Self-tests/Logging not supported

Read SCT Status failed: scsi error aborted command

Read SCT Status failed: scsi error aborted command
SCT (Get) Error Recovery Control command failed

Device Statistics (GP/SMART Log 0x04) not supported

ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: scsi error aborted command
Read SATA Phy Event Counters failed

Change History (4)

comment:1 by Christian Franke, 8 years ago

Milestone: Release 6.6
Priority: majorminor

comment:2 by Christian Franke, 7 years ago

Owner: set to Christian Franke
Status: newaccepted

comment:3 by Christian Franke, 7 years ago

Resolution: fixed
Status: acceptedclosed

comment:4 by Christian Franke, 7 years ago

Merged in r4377.

Note: See TracTickets for help on using tickets.