Opened 10 years ago

Closed 10 years ago

Last modified 10 years ago

#636 closed enhancement (fixed)

Add SAMSUNG MZ7LN128HCHP-00000

Reported by: spacedust Owned by:
Priority: minor Milestone: Release 6.5
Component: drivedb Version: 6.4
Keywords: Cc:

Description

Please add SAMSUNG MZ7LN128HCHP-00000 to the database.

It seems to be Samsung PM-871

smartctl 6.5 2016-01-06 r4198 [x86_64-linux-4.4.0-1.el6.elrepo.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG MZ7LN128HCHP-00000
Serial Number:    S1ZFNXAG701382
LU WWN Device Id: 5 002538 d402b799b
Firmware Version: EMT0100Q
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sun Jan 17 17:27:03 2016 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x53) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  64) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       49
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       3
170 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
173 Unknown_Attribute       0x0033   099   099   005    Pre-fail  Always       -       1
174 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       -       1
178 Used_Rsvd_Blk_Cnt_Chip  0x0013   100   100   010    Pre-fail  Always       -       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0013   100   100   010    Pre-fail  Always       -       386
184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0032   063   056   000    Old_age   Always       -       37
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       -       0
233 Media_Wearout_Indicator 0x0013   099   099   000    Pre-fail  Always       -       16768826
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       -       123
242 Total_LBAs_Read         0x0032   099   099   000    Old_age   Always       -       114
249 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       -       128

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Change History (10)

comment:1 by Christian Franke, 10 years ago

Component: alldrivedb
Priority: majorminor

comment:2 by Andreas E, 10 years ago

-deleted- (I stand corrected - sorry for the noise.)

Last edited 10 years ago by Andreas E (previous) (diff)

comment:3 by spacedust, 10 years ago

Mine is 128GB ;)

comment:4 by Alex Samorukov, 10 years ago

According to http://www.samsung.com/semiconductor/products/flash-storage/client-ssd/ it is PM871 family. Other drives from it:

MZ7LN128HCHP (128)
MZNLN128HCGR (128)
MZ7LN256HCHP (256)
MZNLN256HCHP (256)
MZNLN512HCJH (512)
MZ7LN512HCHP (512)

I did not found yet any SMART attributes documentation for this drives, so probably will just extend "Samsung based SSDs" list.

Last edited 10 years ago by Alex Samorukov (previous) (diff)

comment:5 by Alex Samorukov, 10 years ago

Fixed in r4200, please test.

comment:6 by Alex Samorukov, 10 years ago

Resolution: fixed
Status: newclosed

comment:7 by spacedust, 10 years ago

It works ;)

=== START OF INFORMATION SECTION ===
Model Family:     Samsung based SSDs
Device Model:     SAMSUNG MZ7LN128HCHP-00000
Serial Number:    S1ZFNXAG701382
LU WWN Device Id: 5 002538 d402b799b
Firmware Version: EMT0100Q
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Jan 19 14:06:13 2016 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x53) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  64) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       94
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       3
170 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
173 Unknown_Attribute       0x0033   099   099   005    Pre-fail  Always       -       1
174 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       -       1
178 Used_Rsvd_Blk_Cnt_Chip  0x0013   100   100   010    Pre-fail  Always       -       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0013   100   100   010    Pre-fail  Always       -       386
184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
187 Uncorrectable_Error_Cnt 0x0032   100   100   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0032   062   056   000    Old_age   Always       -       38
199 CRC_Error_Count         0x003e   100   100   000    Old_age   Always       -       0
233 Media_Wearout_Indicator 0x0013   099   099   000    Pre-fail  Always       -       16768826
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       -       154
242 Total_LBAs_Read         0x0032   099   099   000    Old_age   Always       -       140
249 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       -       154

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

comment:8 by spacedust, 10 years ago

173 is Wear Leveller Worst Case Erase Count
174 is Unexpected Power Loss
249 is NAND_Writes_1GiB

comment:9 by spacedust, 10 years ago

Another 256 GB model:

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-4.2.8-1-pve] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG MZ7LN256HCHP-00000
Serial Number:    S1ZENXAGC04598
LU WWN Device Id: 5 002538 d4084ac51
Firmware Version: EMT0100Q
User Capacity:    256,060,514,304 bytes [256 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Mon Mar 21 12:51:44 2016 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x53) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 133) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       240
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       3
170 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
173 Unknown_Attribute       0x0033   099   099   005    Pre-fail  Always       -       1
174 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
178 Used_Rsvd_Blk_Cnt_Chip  0x0013   100   100   010    Pre-fail  Always       -       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0013   100   100   010    Pre-fail  Always       -       791
184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0032   075   068   000    Old_age   Always       -       25
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       -       0
233 Media_Wearout_Indicator 0x0013   099   099   000    Pre-fail  Always       -       16768826
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       -       406
242 Total_LBAs_Read         0x0032   099   099   000    Old_age   Always       -       80
249 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       -       406

SMART Error Log Version: 1
No Errors Logged

Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%        82         -

Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

comment:10 by Christian Franke, 10 years ago

Merged in r4220.

Note: See TracTickets for help on using tickets.