Opened 9 years ago

Closed 9 years ago

#490 closed enhancement (fixed)

Add ADATA SSD SX900 512GB-DL2

Reported by: spacedust Owned by: Christian Franke
Priority: major Milestone: Release 6.4
Component: all Version: 6.3
Keywords: Cc:

Description

Please add ADATA SSD SX900

smartctl 6.3 2014-07-26 r3976 [x86_64-w64-mingw32-win7-sp1] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     ADATA SSD SX900 512GB-DL2
Serial Number:    7D4120008765
LU WWN Device Id: 0 000000 000000000
Firmware Version: 5.8.2
User Capacity:    512 110 190 592 bytes [512 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sat Nov 08 19:37:14 2014
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed

                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x7d) SMART execute Offline immediate.
                                        No Auto Offline data collection support.

                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x0025) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_
FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0032   120   120   050    Old_age   Always       -
       1541893259264
  5 Reallocated_Sector_Ct   0x0033   075   075   003    Pre-fail  Always       -
       12
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -
       7 (213 126 0)
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -
       25
171 Unknown_Attribute       0x000a   100   100   000    Old_age   Always       -
       0
172 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -
       0
174 Unknown_Attribute       0x0030   000   000   000    Old_age   Offline      -
       14
177 Wear_Leveling_Count     0x0000   000   000   000    Old_age   Offline      -
       0
181 Program_Fail_Cnt_Total  0x000a   100   100   000    Old_age   Always       -
       0
182 Erase_Fail_Count_Total  0x0032   100   100   000    Old_age   Always       -
       0
187 Reported_Uncorrect      0x0012   001   001   000    Old_age   Always       -
       46252
194 Temperature_Celsius     0x0022   028   053   000    Old_age   Always       -
       28 (Min/Max 13/53)
195 Hardware_ECC_Recovered  0x001c   120   120   000    Old_age   Offline      -
       1541893259264
196 Reallocated_Event_Count 0x0033   075   075   003    Pre-fail  Always       -
       12
201 Unknown_SSD_Attribute   0x001c   120   120   000    Old_age   Offline      -
       1541893259264
204 Soft_ECC_Correction     0x001c   120   120   000    Old_age   Offline      -
       1541893259264
230 Unknown_SSD_Attribute   0x0013   100   100   000    Pre-fail  Always       -
       100
231 Temperature_Celsius     0x0013   073   073   010    Pre-fail  Always       -
       180388626433
233 Media_Wearout_Indicator 0x0032   000   000   000    Old_age   Always       -
       374
234 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       -
       831
241 Total_LBAs_Written      0x0032   000   000   000    Old_age   Always       -
       831
242 Total_LBAs_Read         0x0032   000   000   000    Old_age   Always       -
       511

SMART Error Log not supported

SMART Self-test log structure revision number 0
Warning: ATA Specification requires self-test log structure revision number = 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Change History (4)

comment:1 by Alex Samorukov, 9 years ago

Owner: set to Alex Samorukov
Status: newassigned

I will take it. It seems that description is available @ http://www.adata.com/AppStore/ADATA%20SSD%20Toolbox_UserGuide_V10_EN.pdf

comment:2 by Christian Franke, 9 years ago

Milestone: Release 6.4

comment:3 by Christian Franke, 9 years ago

Owner: changed from Alex Samorukov to Christian Franke
Status: assignedaccepted

comment:4 by Christian Franke, 9 years ago

Resolution: fixed
Status: acceptedclosed
Note: See TracTickets for help on using tickets.