Opened 14 years ago

Closed 14 years ago

Last modified 4 months ago

#49 closed defect (fixed)

cciss bug smartd/smartd with more than 15 devices

Reported by: Alex Keda Owned by: Christian Franke
Priority: major Milestone: Release 5.40
Component: all Version: 5.39
Keywords: Cc:

Description

with 5.38 I have good working
filez1# smartctl -a --device=cciss,20 /dev/ciss0
smartctl version 5.38 [i386-portbld-freebsd6.3] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

Device: HP DF0300B8053 Version: HPD4
Serial number: 3QP16VEE00009935XQ0P
Device type: disk
Transport protocol: SAS
Local Time is: Thu Feb 4 17:05:15 2010 MSK
Device supports SMART and is Enabled
Temperature Warning Enabled
SMART Health Status: OK

with 5.39 I have it:
filez1# smartctl -a --device=cciss,20 /dev/ciss0
smartctl 5.39 2009-12-09 r2995 [FreeBSD 6.3-RELEASE-p9 i386] (local build)
Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net

/dev/ciss0: Option -d cciss,N (N=20) must have 0 <= N <= 15
=======> VALID ARGUMENTS ARE: ata, scsi, sat[,N][+TYPE], usbcypress[,X], usbjmicron[,x][,N], usbsunplus, 3ware,N, hpt,L/M/N, cciss,N, test <=======

Use smartctl -h to get a usage summary

filez1#

filez1# uname -a
FreeBSD filez1.moskb.local 6.3-RELEASE-p9 FreeBSD 6.3-RELEASE-p9 #0: Thu Apr 16 21:11:30 MSD 2009 lissyara@…:/usr/obj/usr/src/sys/SMP i386
filez1#

Change History (3)

comment:1 by Christian Franke, 14 years ago

Milestone: Release 5.40
Owner: changed from somebody to Christian Franke
Status: newaccepted

comment:2 by Christian Franke, 14 years ago

Resolution: fixed
Status: acceptedclosed

comment:3 by Christian Franke, 4 months ago

Related & late: r5565.

Note: See TracTickets for help on using tickets.