#208 closed defect (invalid)
LSI 2018 MegaRaid INQUIRY failed
Reported by: | georgeherbert | Owned by: | somebody |
---|---|---|---|
Priority: | major | Milestone: | |
Component: | all | Version: | 5.42 |
Keywords: | megaraid linux needinfo | Cc: | george.herbert@…, ema29, jhlaird |
Description
This is possibly related to tickets 46, 140, 197. I am prepared to provide followup and debugging info. Email on cc list is fastest way to get my attention.
Just compiled smartmontools 5.42 on CentOS 5.6, on a SuperMicro blade server with the LSI 2108 MegaRAID type raid controller.
[root@36d sbin]# ./smartctl -a -d megaraid,0 -T permissive /dev/sg0
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.18-238.el5] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
Smartctl open device: /dev/sg0 [megaraid_disk_00] failed: INQUIRY failed
I've tried megaraid,N for N=1 to 32; saw notes that some devices start enumerating at 8 and tried that additionally, iterated through with /dev/sg0 /dev/sg1. No good.
Not sure if this is an underlying bug or user error on my part, but I have tried everything I am aware of and have found on the net so far without success.
Additional info:
[root@36d sbin]# lsscsi -g
[0:2:0:0] disk LSI AOC-USAS2LP-H8iR 2.40 /dev/sda /dev/sg0
[0:2:1:0] disk LSI AOC-USAS2LP-H8iR 2.40 /dev/sdb /dev/sg1
[0:2:5:0] disk LSI AOC-USAS2LP-H8iR 2.40 /dev/sdg /dev/sg5
[root@36d sbin]# /opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -a0
Adapter #0
==============================================================================
Versions
================
Product Name : LSI MegaRAID SAS PCI Express ROMB
Serial No :
FW Package Build: 12.4.0-0012
Mfg. Data
================
Mfg. Date : 00/00/00
Rework Date : 00/00/00
Revision No :
Battery FRU : N/A
Image Versions in Flash:
================
BIOS Version : 3.10.00
FW Version : 2.40.03-0787
Preboot CLI Version: 04.03-002:#%00008
WebBIOS Version : 6.0-3-e_0-Rel
NVDATA Version : 2.03.0047
Boot Block Version : 2.02.00.00-0000
BOOT Version : 01.250.04.219
Pending Images in Flash
================
None
PCI Info
================
Vendor Id : 1000
Device Id : 0079
SubVendorId : 15d9
SubDeviceId : 0700
Host Interface : PCIE
Number of Frontend Port: 0
Device Interface : PCIE
Number of Backend Port: 8
Port : Address
0 50014ee30009d246
1 4433221105000000
2 4433221104000000
3 0000000000000000
4 50014ee30009d08e
5 0000000000000000
6 0000000000000000
7 0000000000000000
HW Configuration
================
SAS Address : 500304800088aaa0
BBU : Absent
Alarm : Present
NVRAM : Present
Serial Debugger : Present
Memory : Present
Flash : Present
Memory Size : 512MB
TPM : Absent
On board Expander: Absent
Upgrade Key : Absent
Temperature sensor for ROC : Absent
Temperature sensor for controller : Absent
Settings
================
Current Time : 3:51:7 11/23, 2011
Predictive Fail Poll Interval : 300sec
Interrupt Throttle Active Count : 16
Interrupt Throttle Completion : 50us
Rebuild Rate : 30%
PR Rate : 30%
BGI Rate : 30%
Check Consistency Rate : 30%
Reconstruction Rate : 30%
Cache Flush Interval : 4s
Max Drives to Spinup at One Time : 2
Delay Among Spinup Groups : 12s
Physical Drive Coercion Mode : 1GB
Cluster Mode : Disabled
Alarm : Enabled
Auto Rebuild : Enabled
Battery Warning : Disabled
Ecc Bucket Size : 15
Ecc Bucket Leak Rate : 1440 Minutes
Restore HotSpare on Insertion : Disabled
Expose Enclosure Devices : Enabled
Maintain PD Fail History : Disabled
Host Request Reordering : Enabled
Auto Detect BackPlane Enabled : SGPIO/i2c SEP
Load Balance Mode : Auto
Use FDE Only : No
Security Key Assigned : No
Security Key Failed : No
Security Key Not Backedup : No
Default LD PowerSave Policy : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 0
Any Offline VD Cache Preserved : No
Allow Boot with Preserved Cache : No
Disable Online Controller Reset : No
PFK in NVRAM : No
Use disk activity for locate : No
Capabilities
================
RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Supported Drives : SAS, SATA
Allowed Mixing:
Mix in Enclosure Allowed
Mix of SAS/SATA of HDD type in VD Allowed
Mix of SAS/SATA of SSD type in VD Allowed
Mix of SSD/HDD in VD Allowed
Status
================
ECC Bucket Count : 0
Limitations
================
Max Arms Per VD : 32
Max Spans Per VD : 8
Max Arrays : 128
Max Number of VDs : 64
Max Parallel Commands : 1008
Max SGE Count : 60
Max Data Transfer Size : 8192 sectors
Max Strips PerIO : 42
Max LD per array : 16
Min Strip Size : 8 KB
Max Strip Size : 1.0 MB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade : 0 GB
Current Size of FW Cache : 0 MB
Device Present
================
Virtual Drives : 2
Degraded : 0
Offline : 0
Physical Devices : 5
Disks : 4
Critical Disks : 0
Failed Disks : 0
Supported Adapter Operations
================
Rebuild Rate : Yes
CC Rate : Yes
BGI Rate : Yes
Reconstruct Rate : Yes
Patrol Read Rate : Yes
Alarm Control : Yes
Cluster Support : No
BBU : Yes
Spanning : Yes
Dedicated Hot Spare : Yes
Revertible Hot Spares : Yes
Foreign Config Import : Yes
Self Diagnostic : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares : Yes
Deny SCSI Passthrough : No
Deny SMP Passthrough : No
Deny STP Passthrough : No
Support Security : No
Snapshot Enabled : No
Support the OCE without adding drives : Yes
Support PFK : No
Support PI : No
Support Boot Time PFK Change : No
Disable Online PFK Change : No
Support Shield State : No
Block SSD Write Disk Cache Change: No
Supported VD Operations
================
Read Policy : Yes
Write Policy : Yes
IO Policy : Yes
Access Policy : Yes
Disk Cache Policy : Yes
Reconstruction : Yes
Deny Locate : No
Deny CC : No
Allow Ctrl Encryption: No
Enable LDBBM : Yes
Support Breakmirror : No
Power Savings : No
Supported PD Operations
================
Force Online : Yes
Force Offline : Yes
Force Rebuild : Yes
Deny Force Failed : No
Deny Force Good/Bad : No
Deny Missing Replace : No
Deny Clear : No
Deny Locate : No
Support Temperature : No
Disable Copyback : No
Enable JBOD : No
Enable Copyback on SMART : No
Enable Copyback to SSD on SMART Error : Yes
Enable SSD Patrol Read : No
PR Correct Unconfigured Areas : Yes
Enable Spin Down of UnConfigured Drives : Yes
Disable Spin Down of hot spares : No
Spin Down time : 30
T10 Power State : No
Error Counters
================
Memory Correctable Errors : 0
Memory Uncorrectable Errors : 0
Cluster Information
================
Cluster Permitted : No
Cluster Active : No
Default Settings
================
Phy Polarity : 0
Phy PolaritySplit : 0
Background Rate : 30
Strip Size : 64kB
Flush Time : 4 seconds
Write Policy : WB
Read Policy : Adaptive
Cache When BBU Bad : Enabled
Cached IO : Yes
SMART Mode : Mode 6
Alarm Disable : Yes
Coercion Mode : 1GB
ZCR Config : Unknown
Dirty LED Shows Drive Activity : No
BIOS Continue on Error : No
Spin Down Mode : None
Allowed Device Type : SAS/SATA Mix
Allow Mix in Enclosure : Yes
Allow HDD SAS/SATA Mix in VD : Yes
Allow SSD SAS/SATA Mix in VD : Yes
Allow HDD/SSD Mix in VD : Yes
Allow SATA in Cluster : No
Max Chained Enclosures : 16
Disable Ctrl-R : Yes
Enable Web BIOS : Yes
Direct PD Mapping : No
BIOS Enumerate VDs : Yes
Restore Hot Spare on Insertion : No
Expose Enclosure Devices : Yes
Maintain PD Fail History : No
Disable Puncturing : No
Zero Based Enclosure Enumeration : No
PreBoot CLI Enabled : Yes
LED Show Drive Activity : Yes
Cluster Disable : Yes
SAS Disable : No
Auto Detect BackPlane Enable : SGPIO/i2c SEP
Use FDE Only : No
Enable Led Header : No
Delay during POST : 0
EnableCrashDump : No
Disable Online Controller Reset : No
EnableLDBBM : Yes
Un-Certified Hard Disk Drives : Allow
Treat Single span R1E as R10 : No
Max LD per array : 16
Power Saving option : All power saving options are enabled
Default spin down time in minutes: 30
Enable JBOD : No
TTY Log In Flash : No
Auto Enhanced Import : No
BreakMirror RAID Support : No
Disable Join Mirror : No
Enable Shield State : No
Time taken to detect CME : 60s
Exit Code: 0x00
Change History (9)
comment:1 by , 13 years ago
Component: | smartctl → all |
---|---|
Keywords: | linux added; inquiry failed removed |
comment:2 by , 13 years ago
Milestone: | → Release 5.43 |
---|
comment:3 by , 13 years ago
Cc: | added |
---|
Also having this issue with a 9260-16i. Adding myself to the CC list.
comment:4 by , 13 years ago
Cc: | added |
---|
Failing here with Dell PERC H800 (9260 rev 05).
PERC 6/i (1078) in the same machine works fine.
comment:5 by , 13 years ago
Whoops.
The device numbers on my 9260 start from 4:
# megacli -pdlist -a0 | grep Id
Device Id: 9
Device Id: 8
Device Id: 4
Device Id: 7
Device Id: 6
Device Id: 5
And using megaraid,4 et cetera works fine.
comment:6 by , 13 years ago
Keywords: | needinfo added |
---|---|
Milestone: | Release 5.43 |
comment:7 by , 13 years ago
Resolution: | → invalid |
---|---|
Status: | new → closed |
Its not a bug, but lack of documentation. MegaRaid numbering is strange and i already saw systems with first disk started from 11. We should just add megacli -pdlist -a0 to the FAQ.
comment:8 by , 13 years ago
Hi, i can provide you a root access to a computer with an LSI MegaRAID SAS 9240 or LSI MegaRAID SAS 9260. Lets me know if you will need one to debug the controller.
BR
Pawel
comment:9 by , 12 years ago
Same problem with the IDs here:
Controller : LSI MegaRAID SAS 9260-8i Firmware : 12.12.0-0102
My drive ID starts by 8:
root@ubuntu:~# MegaCli -pdlist -a0 | grep Id Device Id: 9 Device Id: 8
When i use ID 8 or 9 the smartctl works fine.
smartctl -s on -a -d megaraid,8 /dev/sda
Here a small script to get smart info:
DEVICE=/dev/sda for i in $(MegaCli -pdlist -a0 | grep Id | cut -d":" -f2); do smartctl -s on -a -d megaraid,${i} ${DEVICE} done
Can someone please update the smartctl Wiki an man page so that the user know how to find and use the right ID for those controller?
Thank you
Pawel
same issue on LSI MegaRAID SAS 9260-8i
smartctl -a -d megaraid,0 /dev/sda
smartctl 5.43 2011-12-20 r3499 [x86_64-linux-2.6.35-24-server] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
Smartctl open device: /dev/sda [megaraid_disk_00] failed: INQUIRY failed
Let me know if you need more output.
BR
Pawel
here the controller info:
MegaCli64 -AdpAllInfo -a0
Adapter #0
==============================================================================
Product Name : LSI MegaRAID SAS 9260-8i
Serial No : SVXXXXXXXX
FW Package Build: 12.12.0-0073
Mfg. Date : 09/07/11
Rework Date : 00/00/00
Revision No : 60A
Battery FRU : N/A
FW Version : 2.120.183-1415
BIOS Version : 3.23.00_4.11.05.00_0x05080000
Preboot CLI Version: 04.04-018:#%00008
WebBIOS Version : 6.0-45-e_40-Rel
NVDATA Version : 2.09.03-0024
Boot Block Version : 2.02.00.00-0000
BOOT Version : 09.250.01.219
None
Vendor Id : 1000
Device Id : 0079
SubVendorId : 1000
SubDeviceId : 9261
Host Interface : PCIE
Number of Frontend Port: 0
Device Interface : PCIE
Number of Backend Port: 8
Port : Address
0 5000039358c97cd2
1 5000039378c89f2e
2 5000039378c89b26
3 5000039378c89c72
4 5000039368c8b352
5 5000039378c89f06
6 5000039368c830ce
7 5000039378c89efa
SAS Address : 500605b003acf160
BBU : Present
Alarm : Present
NVRAM : Present
Serial Debugger : Present
Memory : Present
Flash : Present
Memory Size : 512MB
TPM : Absent
On board Expander: Absent
Upgrade Key : Absent
Temperature sensor for ROC : Absent
Temperature sensor for controller : Absent
Current Time : 13:35:25 12/27, 2011
Predictive Fail Poll Interval : 300sec
Interrupt Throttle Active Count : 16
Interrupt Throttle Completion : 50us
Rebuild Rate : 30%
PR Rate : 30%
BGI Rate : 30%
Check Consistency Rate : 30%
Reconstruction Rate : 30%
Cache Flush Interval : 4s
Max Drives to Spinup at One Time : 4
Delay Among Spinup Groups : 2s
Physical Drive Coercion Mode : Disabled
Cluster Mode : Disabled
Alarm : Enabled
Auto Rebuild : Enabled
Battery Warning : Enabled
Ecc Bucket Size : 15
Ecc Bucket Leak Rate : 1440 Minutes
Restore HotSpare on Insertion : Disabled
Expose Enclosure Devices : Enabled
Maintain PD Fail History : Enabled
Host Request Reordering : Enabled
Auto Detect BackPlane Enabled : SGPIO/i2c SEP
Load Balance Mode : Auto
Use FDE Only : No
Security Key Assigned : No
Security Key Failed : No
Security Key Not Backedup : No
Default LD PowerSave Policy : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 120
Any Offline VD Cache Preserved : No
Allow Boot with Preserved Cache : No
Disable Online Controller Reset : No
PFK in NVRAM : No
Use disk activity for locate : No
RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Supported Drives : SAS, SATA
Allowed Mixing:
Mix in Enclosure Allowed
Mix of SAS/SATA of HDD type in VD Allowed
ECC Bucket Count : 0
Max Arms Per VD : 32
Max Spans Per VD : 8
Max Arrays : 128
Max Number of VDs : 64
Max Parallel Commands : 1008
Max SGE Count : 80
Max Data Transfer Size : 8192 sectors
Max Strips PerIO : 42
Min Strip Size : 8 KB
Max Strip Size : 1.0 MB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade : 0 GB
Current Size of FW Cache : 394 MB
Virtual Drives : 1
Physical Devices : 9
Rebuild Rate : Yes
CC Rate : Yes
BGI Rate : Yes
Reconstruct Rate : Yes
Patrol Read Rate : Yes
Alarm Control : Yes
Cluster Support : No
BBU : Yes
Spanning : Yes
Dedicated Hot Spare : Yes
Revertible Hot Spares : Yes
Foreign Config Import : Yes
Self Diagnostic : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares : Yes
Deny SCSI Passthrough : No
Deny SMP Passthrough : No
Deny STP Passthrough : No
Support Security : No
Snapshot Enabled : No
Support the OCE without adding drives : Yes
Support PFK : Yes
PFK TrailTime Remaining : 0 days 0 hours
Read Policy : Yes
Write Policy : Yes
IO Policy : Yes
Access Policy : Yes
Disk Cache Policy : Yes
Reconstruction : Yes
Deny Locate : No
Deny CC : No
Allow Ctrl Encryption: No
Enable LDBBM : No
Support Breakmirror : No
Power Savings : No
Force Online : Yes
Force Offline : Yes
Force Rebuild : Yes
Deny Force Failed : No
Deny Force Good/Bad : No
Deny Missing Replace : No
Deny Clear : No
Deny Locate : No
Support Temperature : Yes
Disable Copyback : No
Enable JBOD : Yes
Enable Copyback on SMART : No
Enable Copyback to SSD on SMART Error : Yes
Enable SSD Patrol Read : No
PR Correct Unconfigured Areas : Yes
Enable Spin Down of UnConfigured Drives : Yes
Disable Spin Down of hot spares : No
Spin Down time : 30
T10 Power State : No
Memory Correctable Errors : 0
Memory Uncorrectable Errors : 0
Cluster Permitted : No
Cluster Active : No
Phy Polarity : 0
Phy PolaritySplit : 0
Background Rate : 30
Strip Size : 64kB
Flush Time : 4 seconds
Write Policy : WB
Read Policy : Adaptive
Cache When BBU Bad : Disabled
Cached IO : No
SMART Mode : Mode 6
Alarm Disable : Yes
Coercion Mode : None
ZCR Config : Unknown
Dirty LED Shows Drive Activity : No
BIOS Continue on Error : No
Spin Down Mode : None
Allowed Device Type : SAS/SATA Mix
Allow Mix in Enclosure : Yes
Allow HDD SAS/SATA Mix in VD : Yes
Allow SSD SAS/SATA Mix in VD : No
Allow HDD/SSD Mix in VD : No
Allow SATA in Cluster : No
Max Chained Enclosures : 16
Disable Ctrl-R : Yes
Enable Web BIOS : Yes
Direct PD Mapping : No
BIOS Enumerate VDs : Yes
Restore Hot Spare on Insertion : No
Expose Enclosure Devices : Yes
Maintain PD Fail History : Yes
Disable Puncturing : No
Zero Based Enclosure Enumeration : No
PreBoot CLI Enabled : Yes
LED Show Drive Activity : Yes
Cluster Disable : Yes
SAS Disable : No
Auto Detect BackPlane Enable : SGPIO/i2c SEP
Use FDE Only : No
Enable Led Header : Yes
Delay during POST : 0
EnableCrashDump : No
Disable Online Controller Reset : No
EnableLDBBM : No
Un-Certified Hard Disk Drives : Allow
Treat Single span R1E as R10 : No
Max LD per array : 16
Power Saving option : Don't Auto spin down Configured Drives
Max power savings option is not allowed for LDs. Only T10 power conditions are to be used.
Default spin down time in minutes: 30
Enable JBOD : No
TTY Log In Flash : No
Auto Enhanced Import : No
BreakMirror RAID Support : No
Disable Join Mirror : No
Time taken to detect CME : 60s
Exit Code: 0x00