id,summary,reporter,owner,description,type,status,priority,milestone,component,version,resolution,keywords,cc 1538,smartd gets confused about which drive is reporting temperature changes?,Jimmie,,"OS: OpenSUSE Leap 15.3 (x86-64) smartmontools version 7.0-6.1 I've received a number of smartd email notifications over the past few weeks. Every time, the system journal suggests that smartd detected a temperature change on /dev/sda but that an error was logged against /dev/nvme. My system has two SSDs: /dev/sda: Samsung 850 EVO /dev/nvme0: SK Hynix P31 The following warning/error was logged by the smartd daemon today: {{{ Device: /dev/nvme0, number of Error Log entries increased from 11 to 12 Device info: SHGP31-1000GM-2, S/N:XXXXXX, FW:41060C20 }}} The system journal from that timestamp shows the following: {{{ smartd[1511]: Device: /dev/sda [SAT], SMART Usage Attribute: 190 Airflow_Temperature_Cel changed from 74 [Raw 26] to 73 [Raw 27] smartd[1511]: Device: /dev/nvme0, number of Error Log entries increased from 11 to 12 smartd[1511]: Sending warning via to xxxxxxxx@xxxxxxxx ... smartd[1511]: Warning via to xxxxxx@xxxxxxxx: successful }}} For some reason, it looks like smartd logged the error against /dev/nvme0? ",defect,closed,minor,,smartd,7.0,invalid,,