Opened 4 years ago

Last modified 4 years ago

#1293 closed enhancement

drivedb.h Fix for PLEXTOR PX-128M3 — at Version 2

Reported by: sterling pickens Owned by:
Priority: minor Milestone: Release 7.2
Component: drivedb Version: 7.1
Keywords: ssd Cc:

Description (last modified by Christian Franke)

My SSD has an extra space "PLEXTOR PX-128M3" so it is not detected.

this change to the regex fixes it:

-"PLEXTOR PX-(64|128|256|512|768)M(3P?|5[MPS]|5Pro|6[MS])\\+?",
+"PLEXTOR.*PX-(64|128|256|512|768)M(3P?|5[MPS]|5Pro|6[MS])\\+?",

Maybe this is because I have firmware 1.00

=== START OF INFORMATION SECTION ===
Model Family:     Plextor M3/M5/M6 Series SSDs
Device Model:     PLEXTOR  PX-128M3
Serial Number:    002150101377
LU WWN Device Id: 5 000000 000000000
Firmware Version: 1.00
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a
SATA Version is:  SATA 3.0, 6.0 Gb/s
Local Time is:    Thu Jan 30 09:30:05 2020 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

...

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0003   100   100   070    Pre-fail  Always       -       0
  5 Reallocated_Sector_Ct   0x0003   100   100   000    Pre-fail  Always       -       16384 (0 22)
  9 Power_On_Hours          0x0002   100   100   000    Old_age   Always       -       72343
 12 Power_Cycle_Count       0x0002   100   100   000    Old_age   Always       -       18
178 Used_Rsvd_Blk_Cnt_Chip  0x0003   100   100   000    Pre-fail  Always       -       88
187 Reported_Uncorrect      0x0002   100   100   000    Old_age   Always       -       178
192 Power-Off_Retract_Count 0x0003   100   100   000    Pre-fail  Always       -       19

Also it seems this SSD has Reallocated sectors and is failing ?

thanks,
sterling

Change History (2)

comment:1 by sterling pickens, 4 years ago

It seems 2 spaces are turned to one when you post here.
My "PLEXTOR PX-" has 2 spaces between those words.

comment:2 by Christian Franke, 4 years ago

Description: modified (diff)
Note: See TracTickets for help on using tickets.