Opened 5 years ago
Closed 5 years ago
#1293 closed enhancement (fixed)
drivedb.h Fix for PLEXTOR PX-128M3
Reported by: | sterling pickens | Owned by: | Christian Franke |
---|---|---|---|
Priority: | minor | Milestone: | Release 7.2 |
Component: | drivedb | Version: | 7.1 |
Keywords: | ssd | Cc: |
Description (last modified by )
My SSD has an extra space "PLEXTOR PX-128M3" so it is not detected.
this change to the regex fixes it:
-"PLEXTOR PX-(64|128|256|512|768)M(3P?|5[MPS]|5Pro|6[MS])\\+?", +"PLEXTOR.*PX-(64|128|256|512|768)M(3P?|5[MPS]|5Pro|6[MS])\\+?",
Maybe this is because I have firmware 1.00
=== START OF INFORMATION SECTION === Model Family: Plextor M3/M5/M6 Series SSDs Device Model: PLEXTOR PX-128M3 Serial Number: 002150101377 LU WWN Device Id: 5 000000 000000000 Firmware Version: 1.00 User Capacity: 128,035,676,160 bytes [128 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a SATA Version is: SATA 3.0, 6.0 Gb/s Local Time is: Thu Jan 30 09:30:05 2020 MST SMART support is: Available - device has SMART capability. SMART support is: Enabled ... SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0003 100 100 070 Pre-fail Always - 0 5 Reallocated_Sector_Ct 0x0003 100 100 000 Pre-fail Always - 16384 (0 22) 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 72343 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 18 178 Used_Rsvd_Blk_Cnt_Chip 0x0003 100 100 000 Pre-fail Always - 88 187 Reported_Uncorrect 0x0002 100 100 000 Old_age Always - 178 192 Power-Off_Retract_Count 0x0003 100 100 000 Pre-fail Always - 19
Also it seems this SSD has Reallocated sectors and is failing ?
thanks,
sterling
Change History (8)
comment:1 by , 5 years ago
comment:2 by , 5 years ago
Description: | modified (diff) |
---|
comment:3 by , 5 years ago
Keywords: | ssd added; drivedb.h PLEXTOR PX-128M3 removed |
---|---|
Milestone: | → Release 7.2 |
Type: | defect → enhancement |
Another drive with two spaces in identify string (other: Kingston A400, WD Blue SSD). Typo or obfuscated encoding of something (OEM, region, distribution channel, ...)?
The regex above is too coarse as it would match also possible future names like PLEXTOR TOPX-...
.
Better:
"PLEXTOR ?PX-(64|128|256|512|768)M(3P?|5[MPS]|5Pro|6[MS])\\+?",
PS: In future submissions, please do not discard the first smartctl output line. It contains important information about smartctl version and platform. Include a full smartctl -x
report if possible.
comment:4 by , 5 years ago
Also it seems this SSD has Reallocated sectors and is failing ?
Possibly - or this attribute means something different. Are 72343 Power_on_Hours (more than 8 years) correct? If yes, I would retire the drive :-)
comment:5 by , 5 years ago
Yes, I ran it in a webserver for years.
The Power_Cycle_Count number is correct too :)
I tried to update the firmware, and it errors with a cmd timeout.
So I guess it is toast.
comment:6 by , 5 years ago
I managed to update the firmware from 1.00 to 1.07 and the extra space is gone.
So this would apply to drives without the latest fw.
comment:7 by , 5 years ago
Owner: | set to |
---|---|
Status: | new → accepted |
It seems 2 spaces are turned to one when you post here.
My "PLEXTOR PX-" has 2 spaces between those words.