Opened 6 years ago
Closed 5 years ago
#1272 closed defect (duplicate)
Missing SMART data from hpsa SAS devices (HP EG0900FBLSK)
| Reported by: | Dustin Marquess | Owned by: | |
|---|---|---|---|
| Priority: | minor | Milestone: | Release 7.2 |
| Component: | all | Version: | |
| Keywords: | cciss linux scsi | Cc: |
Description (last modified by )
NEW
$ sudo ./smartctl -x -d scsi+cciss,0 -r ioctl /dev/sg0 < smartctl 7.1 2019-12-13 r5004 [x86_64-linux-4.18.13-geo1.ol6.x86_64] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 === START OF INFORMATION SECTION === Vendor: HP Product: EG0900FBLSK Revision: HPD8 Compliance: SPC-3 cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 User Capacity: 900,185,481,216 bytes [900 GB] Logical block size: 512 bytes cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 Rotation Rate: 10000 rpm Form Factor: 2.5 inches cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 Logical Unit id: 0x5000c5004bc2745b cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 Serial number: 6XS22P5S0000B235E1D7 Device type: disk Transport protocol: SAS (SPL-3) Local Time is: Fri Dec 20 14:21:58 2019 PST cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 SMART support is: Available - device has SMART capability. SMART support is: Enabled Temperature Warning: Enabled cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 Read Cache is: Enabled Writeback Cache is: Enabled === START OF READ SMART DATA SECTION === cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 SMART Health Status: OK Current Drive Temperature: 0 C Drive Trip Temperature: 0 C cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 Elements in grown defect list: 0 Error Counter logging not supported cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01 status=0 Device does not support Self Test logging Device does not support Background scan results logging
OLD
smartctl 5.43 2016-09-28 r4347 [x86_64-linux-4.18.13-geo1.ol6.x86_64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
/dev/sg0 [cciss_disk_00] [SCSI]: Device open changed type from 'sat,auto' to 'cciss'
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Vendor: HP
Product: EG0900FBLSK
Revision: HPD8
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
User Capacity: 900,185,481,216 bytes [900 GB]
Logical block size: 512 bytes
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Logical Unit id: 0x5000c5004bc2745b
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Serial number: 6XS22P5S0000B235E1D7
Device type: disk
Transport protocol: SAS
Local Time is: Fri Dec 20 14:25:23 2019 PST
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Device supports SMART and is Enabled
Temperature Warning Enabled
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
SMART Health Status: OK
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Current Drive Temperature: 21 C
Drive Trip Temperature: 65 C
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Manufactured in week 10 of year 2012
Specified cycle count over device lifetime: 10000
Accumulated start-stop cycles: 60
Specified load-unload count over device lifetime: 300000
Accumulated load-unload cycles: 1513
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Elements in grown defect list: 0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Vendor (Seagate) cache information
Blocks sent to initiator = 773829256
Blocks received from initiator = 4244589878
Blocks read from cache and sent to initiator = 4231434536
Number of read and write commands whose size <= segment size = 3949760769
Number of read and write commands whose size > segment size = 39300
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Vendor (Seagate/Hitachi) factory information
number of hours powered up = 60047.63
number of minutes until next internal SMART test = 59
Vendor (Seagate/Hitachi) factory lpage: unknown parameter code [0x9]
Vendor (Seagate/Hitachi) factory lpage: unknown parameter code [0xe]
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Error counter log:
Errors Corrected by Total Correction Gigabytes Total
ECC rereads/ errors algorithm processed uncorrected
fast | delayed rewrites corrected invocations [10^9 bytes] errors
read: 0 0 0 782369620 0 4012475.671 0
write: 0 0 0 0 0 28874.763 0
verify: 0 0 0 3275645858 0 476.546 0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Non-medium error count: 162
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
SMART Self-test log
Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ]
Description number (hours)
# 1 Background short Completed - 0 - [- - -]
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Long (extended) Self Test duration: 7250 seconds [120.8 minutes]
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Background scan results log
Status: scan is active
Accumulated power on time, hours:minutes 60047:38 [3602858 minutes]
Number of background scans performed: 2229, scan progress: 2.06%
Number of background medium scans performed: 2229
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
Protocol Specific port log page for SAS SSP
relative target port id = 1
generation code = 0
number of phys = 1
phy identifier = 0
attached device type: end device
attached reason: unknown
reason: hard reset
negotiated logical link rate: phy enabled; 6 Gbps
attached initiator port: ssp=1 stp=1 smp=1
attached target port: ssp=0 stp=0 smp=0
SAS address = 0x5000c5004bc27459
attached SAS address = 0x5001438010eef5e0
attached phy identifier = 0
Invalid DWORD count = 0
Running disparity error count = 0
Loss of DWORD synchronization = 18
Phy reset problem = 0
Phy event descriptors:
Invalid word count: 0
Running disparity error count: 0
Loss of dword synchronization count: 18
Phy reset problem count: 0
relative target port id = 2
generation code = 0
number of phys = 1
phy identifier = 1
attached device type: no device attached
attached reason: unknown
reason: unknown
negotiated logical link rate: phy enabled; 1.5 Gbps
attached initiator port: ssp=0 stp=0 smp=0
attached target port: ssp=0 stp=0 smp=0
SAS address = 0x5000c5004bc2745a
attached SAS address = 0x0
attached phy identifier = 0
Invalid DWORD count = 0
Running disparity error count = 0
Loss of DWORD synchronization = 0
Phy reset problem = 0
Phy event descriptors:
Invalid word count: 0
Running disparity error count: 0
Loss of dword synchronization count: 0
Phy reset problem count: 0
Attachments (2)
Change History (14)
comment:1 by , 6 years ago
| Description: | modified (diff) |
|---|
comment:2 by , 6 years ago
| Keywords: | scsi added |
|---|
comment:3 by , 6 years ago
comment:4 by , 6 years ago
| Keywords: | cciss linux added |
|---|---|
| Milestone: | → undecided |
comment:5 by , 6 years ago
Due to their size, I added the out/new -r ioctl2 output as attachments. Had to gzip them to get them to fit the 1MB limit, sorry! :(.
comment:6 by , 6 years ago
Possibly not CCISS related but another side effect of bogus subpages (see #1239).
comment:7 by , 6 years ago
| Summary: | Latest build isn't pulling full SMART data on hpsa devices → Missing SMART data from hpsa SAS devices (HP EG0900FBLSK) |
|---|
comment:8 by , 6 years ago
If possible, please test whether the problem also occurs with a similar disk when connected to a non-RAID controller.
comment:10 by , 5 years ago
Please test r5074 if possible. See https://builds.smartmontools.org/ for source tarball and various binaries.
comment:12 by , 5 years ago
| Milestone: | undecided → Release 7.2 |
|---|---|
| Resolution: | → duplicate |
| Status: | new → closed |
Note:
See TracTickets
for help on using tickets.

Could you please repeat with "-r ioctl,2" ?
Thank you