Read NVMe SMART/Health Information failed: NVMe Status 0x6002 — at Version 2

Reported by: Sider Owned by:
Priority: major Milestone: Release 7.0
Component: all Version: 6.6
Keywords: nvme Cc:

Description (last modified by Christian Franke)

Hello,

There is a problem with reading SMART data from NVMe drive Toshiba RC100. Is there a workaround? Web search didn't bring any result, even didn't description of the error code.
Here is full output:

sider@nas:~$ sudo smartctl -x /dev/nvme0n1
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-39-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       TOSHIBA-RC100
Serial Number:                      48APA0S7PW6S
Firmware Version:                   ADRA0101
PCI Vendor/Subsystem ID:            0x1179
IEEE OUI Identifier:                0x00080d
Controller ID:                      0
Number of Namespaces:               1
Namespace 1 Size/Capacity:          240 057 409 536 [240 GB]
Namespace 1 Formatted LBA Size:     512
Local Time is:                      Wed Nov 21 11:55:13 2018 MSK
Firmware Updates (0x12):            1 Slot, no Reset required
Optional Admin Commands (0x0017):   Security Format Frmw_DL *Other*
Optional NVM Commands (0x0017):     Comp Wr_Unc DS_Mngmt Sav/Sel_Feat
Maximum Data Transfer Size:         512 Pages
Warning  Comp. Temp. Threshold:     82 Celsius
Critical Comp. Temp. Threshold:     85 Celsius

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +     3.30W       -        -    0  0  0  0        0       0
 1 +     2.70W       -        -    1  1  1  1        0       0
 2 +     2.30W       -        -    2  2  2  2        0       0
 3 -   0.0500W       -        -    4  4  4  4    10000   45000
 4 -   0.0050W       -        -    4  4  4  4    10000   50000

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 -    4096       0         0
 1 +     512       0         3

=== START OF SMART DATA SECTION ===
Read NVMe SMART/Health Information failed: NVMe Status 0x6002

Change History (2)

comment:1 by Sider, 5 years ago

Keywords: nvme added

comment:2 by Christian Franke, 5 years ago

Description: modified (diff)
Note: See TracTickets for help on using tickets.