Opened 5 years ago

Last modified 5 years ago

#1134 closed defect

Read NVMe SMART/Health Information failed: NVMe Status 0x6002 — at Initial Version

Reported by: Sider Owned by:
Priority: major Milestone: Release 7.0
Component: all Version: 6.6
Keywords: nvme Cc:

Description

Hello,

There is a problem with reading SMART data from NVMe drive Toshiba RC100. Is there a workaround? Web search didn't bring any result, even didn't description of the error code.
Here is full output:

sider@nas:~$ sudo smartctl -x /dev/nvme0n1
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-39-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

START OF INFORMATION SECTION

Model Number: TOSHIBA-RC100
Serial Number: 48APA0S7PW6S
Firmware Version: ADRA0101
PCI Vendor/Subsystem ID: 0x1179
IEEE OUI Identifier: 0x00080d
Controller ID: 0
Number of Namespaces: 1
Namespace 1 Size/Capacity: 240 057 409 536 [240 GB]
Namespace 1 Formatted LBA Size: 512
Local Time is: Wed Nov 21 11:55:13 2018 MSK
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL *Other*
Optional NVM Commands (0x0017): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 82 Celsius
Critical Comp. Temp. Threshold: 85 Celsius

Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat

0 + 3.30W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.30W - - 2 2 2 2 0 0
3 - 0.0500W - - 4 4 4 4 10000 45000
4 - 0.0050W - - 4 4 4 4 10000 50000

Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf

0 - 4096 0 0
1 + 512 0 3

START OF SMART DATA SECTION

Read NVMe SMART/Health Information failed: NVMe Status 0x6002

Change History (0)

Note: See TracTickets for help on using tickets.