add to drivedb: Innodisk 3IE4 MLC 32GB DHS25-32GM41BW1DC-A90
| Reported by: | jeremy385892a | Owned by: | |
|---|---|---|---|
| Priority: | minor | Milestone: | unscheduled |
| Component: | drivedb | Version: | 6.6 |
| Keywords: | ssd | Cc: |
Description (last modified by )
Could you add the following disk reference in the smartctl database ?
Here is the smartctl -a output:
>smartctl -a /dev/ada0
smartctl 6.3 2014-07-26 r3976 [NS-BSD 3.7.0- amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: 2.5" SATA SSD 3IE4
Serial Number: B0021810230060001
LU WWN Device Id: 5 02b2a2 01d1c1b1a
Firmware Version: L17606i
User Capacity: 32,017,047,552 bytes [32,0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 (unknown minor revision code: 0x011b)
SATA Version is: SATA >3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Jan 3 01:46:44 2012 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Total time to complete Offline
data collection: ( 32) seconds.
Offline data collection
capabilities: (0x00) Offline data collection not supp
orted.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging NOT supported.
General Purpose Logging supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0000 000 000 000 Old_age Offline - 0
2 Throughput_Performance 0x0000 000 000 000 Old_age Offline - 0
5 Reallocated_Sector_Ct 0x0012 100 100 001 Old_age Always - 0
7 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0
8 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0
9 Power_On_Hours 0x0012 025 000 000 Old_age Always - 230
10 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0
12 Power_Cycle_Count 0x0012 020 000 000 Old_age Always - 20
163 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 9
168 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 0
169 Unknown_Attribute 0x0000 100 000 000 Old_age Offline - 100
175 Program_Fail_Count_Chip 0x0000 000 000 000 Old_age Offline - 0
192 Power-Off_Retract_Count 0x0012 000 000 000 Old_age Always - 9
194 Temperature_Celsius 0x0002 055 100 000 Old_age Always - 55 (3 62 0 35 0)
197 Current_Pending_Sector 0x0000 000 000 000 Old_age Offline - 0
225 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0
240 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0
165 Unknown_Attribute 0x0012 043 100 000 Old_age Always - 43
167 Unknown_Attribute 0x0012 000 100 000 Old_age Always - 36
170 Unknown_Attribute 0x0013 100 100 010 Pre-fail Always - 142
171 Unknown_Attribute 0x0012 000 100 000 Old_age Always - 0
172 Unknown_Attribute 0x0012 000 100 000 Old_age Always - 0
176 Erase_Fail_Count_Chip 0x0000 000 000 000 Old_age Offline - 0
184 End-to-End_Error 0x0012 000 000 000 Old_age Always - 0
187 Reported_Uncorrect 0x0012 000 000 000 Old_age Always - 0
229 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 89569723955864
232 Available_Reservd_Space 0x0013 000 000 000 Pre-fail Always - 0
235 Unknown_Attribute 0x0002 000 000 000 Old_age Always - 0
241 Total_LBAs_Written 0x0002 100 100 000 Old_age Always - 35681
242 Total_LBAs_Read 0x0002 100 100 000 Old_age Always - 28410
SMART Error Log not supported
SMART Self-test Log not supported
Selective Self-tests/Logging not supported
Change History (4)
comment:1 by , 7 years ago
| Description: | modified (diff) |
|---|
comment:2 by , 7 years ago
comment:3 by , 7 years ago
| Keywords: | ssd added |
|---|
comment:4 by , 6 years ago
Variants:
DHS25-08GM41BC1SC
DHS25-08GM41BC1DC
DHS25-16GM41BC1DC
DHS25-32GM41BC1DC
DHS25-64GM41BC1DC
DHS25-A28M41BC1DC
DHS25-08GM41BW1SC
DHS25-08GM41BW1DC
DHS25-16GM41BC1DC
DHS25-32GM41BW1DC
DHS25-64GM41BW1DC
DHS25-A28M41BW1DC
regexp: DHS25-A?(08|16|32|64|28)G?M41B[CW]1[DS]C