# smartctl -d sat -q noserial -x /dev/sdb smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.14.0-2-amd64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Device Model: WDC WD30EZRZ-00Z5HB0 Firmware Version: 80.00A80 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Jan 6 20:25:43 2018 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unknown === START OF READ SMART DATA SECTION === SMART Status not supported: Incomplete response, ATA output registers missing SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (40080) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 402) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x7035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 182 181 021 - 5891 4 Start_Stop_Count -O--CK 100 100 000 - 7 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 100 100 000 - 7 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 6 192 Power-Off_Retract_Count -O--CK 200 200 000 - 0 193 Load_Cycle_Count -O--CK 200 200 000 - 17 194 Temperature_Celsius -O---K 109 108 000 - 41 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log 0xb7 GPL,SL VS 39 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Conveyance offline Completed without error 00% 0 - # 2 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) SCT Support Level: 1 Device State: Active (0) Current Temperature: 42 Celsius Power Cycle Min/Max Temperature: 20/42 Celsius Lifetime Min/Max Temperature: 18/42 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (474) Index Estimated Time Temperature Celsius 475 2018-01-06 12:28 ? - ... ..( 2 skipped). .. - 0 2018-01-06 12:31 ? - 1 2018-01-06 12:32 20 * 2 2018-01-06 12:33 ? - 3 2018-01-06 12:34 20 * 4 2018-01-06 12:35 21 ** 5 2018-01-06 12:36 ? - 6 2018-01-06 12:37 18 - ... ..( 2 skipped). .. - 9 2018-01-06 12:40 18 - 10 2018-01-06 12:41 ? - 11 2018-01-06 12:42 19 - 12 2018-01-06 12:43 19 - 13 2018-01-06 12:44 19 - 14 2018-01-06 12:45 20 * 15 2018-01-06 12:46 21 ** 16 2018-01-06 12:47 21 ** 17 2018-01-06 12:48 21 ** 18 2018-01-06 12:49 ? - 19 2018-01-06 12:50 22 *** 20 2018-01-06 12:51 22 *** 21 2018-01-06 12:52 22 *** 22 2018-01-06 12:53 ? - 23 2018-01-06 12:54 21 ** 24 2018-01-06 12:55 20 * 25 2018-01-06 12:56 21 ** 26 2018-01-06 12:57 21 ** 27 2018-01-06 12:58 22 *** 28 2018-01-06 12:59 22 *** 29 2018-01-06 13:00 23 **** 30 2018-01-06 13:01 23 **** 31 2018-01-06 13:02 23 **** 32 2018-01-06 13:03 ? - 33 2018-01-06 13:04 24 ***** 34 2018-01-06 13:05 24 ***** 35 2018-01-06 13:06 24 ***** 36 2018-01-06 13:07 25 ****** 37 2018-01-06 13:08 25 ****** 38 2018-01-06 13:09 25 ****** 39 2018-01-06 13:10 26 ******* 40 2018-01-06 13:11 26 ******* 41 2018-01-06 13:12 27 ******** ... ..( 2 skipped). .. ******** 44 2018-01-06 13:15 27 ******** 45 2018-01-06 13:16 28 ********* ... ..( 2 skipped). .. ********* 48 2018-01-06 13:19 28 ********* 49 2018-01-06 13:20 29 ********** 50 2018-01-06 13:21 29 ********** 51 2018-01-06 13:22 29 ********** 52 2018-01-06 13:23 30 *********** 53 2018-01-06 13:24 30 *********** 54 2018-01-06 13:25 31 ************ ... ..( 4 skipped). .. ************ 59 2018-01-06 13:30 31 ************ 60 2018-01-06 13:31 32 ************* ... ..( 2 skipped). .. ************* 63 2018-01-06 13:34 32 ************* 64 2018-01-06 13:35 33 ************** ... ..( 2 skipped). .. ************** 67 2018-01-06 13:38 33 ************** 68 2018-01-06 13:39 34 *************** ... ..( 2 skipped). .. *************** 71 2018-01-06 13:42 34 *************** 72 2018-01-06 13:43 35 **************** ... ..( 3 skipped). .. **************** 76 2018-01-06 13:47 35 **************** 77 2018-01-06 13:48 36 ***************** ... ..( 10 skipped). .. ***************** 88 2018-01-06 13:59 36 ***************** 89 2018-01-06 14:00 37 ****************** ... ..( 5 skipped). .. ****************** 95 2018-01-06 14:06 37 ****************** 96 2018-01-06 14:07 38 ******************* ... ..( 7 skipped). .. ******************* 104 2018-01-06 14:15 38 ******************* 105 2018-01-06 14:16 39 ******************** ... ..( 9 skipped). .. ******************** 115 2018-01-06 14:26 39 ******************** 116 2018-01-06 14:27 40 ********************* ... ..( 13 skipped). .. ********************* 130 2018-01-06 14:41 40 ********************* 131 2018-01-06 14:42 41 ********************** ... ..( 80 skipped). .. ********************** 212 2018-01-06 16:03 41 ********************** 213 2018-01-06 16:04 42 *********************** ... ..(260 skipped). .. *********************** 474 2018-01-06 20:25 42 *********************** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 27042 Vendor specific