Microsoft Windows [Version 6.1.7601] Copyright (c) 2009 Microsoft Corporation. All rights reserved. C:\smartmon>smartctl.exe --scan /dev/sdb -d scsi # /dev/sdb, SCSI device /dev/sdc -d scsi # /dev/sdc, SCSI device /dev/sdd -d ata # /dev/sdd, ATA device C:\smartmon>smartctl.exe -A /dev/sdb smartctl 6.6 (build date Jun 28 2017) [x86_64-pc-msys-2008r2-sp1] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF READ SMART DATA SECTION === Current Drive Temperature: 38 C Drive Trip Temperature: 63 C Manufactured in week 39 of year 2014 Specified cycle count over device lifetime: 0 Accumulated start-stop cycles: 6398 ID# ATTRIBUTE_NAME VALUE THRESH WORST 1 Raw_Read_Err_Rate 2 200 6 2 Flash_ROM_Check 0 100 0 5 Reallocated_Blk_Ct 0 49912 0 9 Power_ON_Hours 3396 0 3396 12 Power_Cycle_Ct 6398 0 6398 13 ECC_Rate 32 65535 32 29 Pwr_Fail_Backup_Circuit 100 0 100 32 Avg_Write_Amplification 0 0 539 177 Drive_Life_Remain% 99 2 99 178 Drive_Life_Remain_x100 9853 200 9853 180 Unused_Reserved_Blk_Ct 47643 0 47643 181 Program_Fail_Ct 0 0 0 182 Erase_Fail_Ct 0 0 0 190 Drive_Temp_Warning 45 65 65 194 Drive_Temperature 45 70 65 195 UECC_Ct 0 0 0 198 Offline_Scan_UEC 0 0 0 233 Number_Of_LBA_Written 335479 0 335479 245 DriveLife_Used% 1 98 1 246 DriveLife_Used%x100 147 9800 147 defect list format 6 unknown Elements in grown defect list: 0 C:\smartmon>smartctl.exe -x /dev/sdb smartctl 6.6 (build date Jun 28 2017) [x86_64-pc-msys-2008r2-sp1] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: SanDisk Product: DOPE1920S5xnNMRI Revision: P018 Compliance: SPC-4 User Capacity: 1,950,389,400,960 bytes [1.95 TB] Logical block size: 520 bytes Physical block size: 4160 bytes LU is resource provisioned, LBPRZ=1 Rotation Rate: Solid State Device Form Factor: 2.5 inches Logical Unit id: 0x5001173100309154 Serial number: FG00F2HW Device type: disk Transport protocol: SAS (SPL-3) Local Time is: Tue Oct 17 14:10:53 2017 IST SMART support is: Available - device has SMART capability. SMART support is: Enabled Temperature Warning: Enabled Read Cache is: Enabled Writeback Cache is: Disabled === START OF READ SMART DATA SECTION === SMART Health Status: OK Percentage used endurance indicator: 1% Current Drive Temperature: 38 C Drive Trip Temperature: 63 C Manufactured in week 39 of year 2014 Specified cycle count over device lifetime: 0 Accumulated start-stop cycles: 6398 ID# ATTRIBUTE_NAME VALUE THRESH WORST 1 Raw_Read_Err_Rate 2 200 6 2 Flash_ROM_Check 0 100 0 5 Reallocated_Blk_Ct 0 49912 0 9 Power_ON_Hours 3396 0 3396 12 Power_Cycle_Ct 6398 0 6398 13 ECC_Rate 32 65535 32 29 Pwr_Fail_Backup_Circuit 100 0 100 32 Avg_Write_Amplification 0 0 539 177 Drive_Life_Remain% 99 2 99 178 Drive_Life_Remain_x100 9853 200 9853 180 Unused_Reserved_Blk_Ct 47643 0 47643 181 Program_Fail_Ct 0 0 0 182 Erase_Fail_Ct 0 0 0 190 Drive_Temp_Warning 45 65 65 194 Drive_Temperature 45 70 65 195 UECC_Ct 0 0 0 198 Offline_Scan_UEC 0 0 0 233 Number_Of_LBA_Written 335479 0 335479 245 DriveLife_Used% 1 98 1 246 DriveLife_Used%x100 147 9800 147 defect list format 6 unknown Elements in grown defect list: 0 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 0 0 0 0 0 1.020 0 write: 0 0 0 0 0 0.708 0 verify: 0 0 0 0 0 2.430 0 Non-medium error count: 30781 No self-tests have been logged Background scan results log Status: no scans active Accumulated power on time, hours:minutes 3396:42 [203802 minutes] Number of background scans performed: 0, scan progress: 0.00% Number of background medium scans performed: 0 # when lba(hex) [sk,asc,ascq] reassign_status 1 0:00 0000000000000000 [0,0,0] Reserved [0x0] Protocol Specific port log page for SAS SSP relative target port id = 1 generation code = 1 number of phys = 1 phy identifier = 0 attached device type: SAS or SATA device attached reason: loss of dword synchronization reason: power on negotiated logical link rate: phy enabled; 6 Gbps attached initiator port: ssp=1 stp=1 smp=1 attached target port: ssp=0 stp=0 smp=0 SAS address = 0x5001173100309155 attached SAS address = 0x500605b0091c3bf0 attached phy identifier = 4 Invalid DWORD count = 0 Running disparity error count = 0 Loss of DWORD synchronization = 0 Phy reset problem = 0 Phy event descriptors: Invalid word count: 0 Running disparity error count: 0 Loss of dword synchronization count: 0 Phy reset problem count: 0 phy identifier = 0 attached device type: no device attached attached reason: unknown reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator port: ssp=0 stp=0 smp=0 attached target port: ssp=0 stp=0 smp=0 SAS address = 0x2 attached SAS address = 0x0 attached phy identifier = 0 Invalid DWORD count = 0 Running disparity error count = 4 Loss of DWORD synchronization = 0 Phy reset problem = 0 relative target port id = 2 generation code = 1 number of phys = 1 phy identifier = 1 attached device type: no device attached attached reason: unknown reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator port: ssp=0 stp=0 smp=0 attached target port: ssp=0 stp=0 smp=0 SAS address = 0x5001173100309156 attached SAS address = 0x0 attached phy identifier = 0 Invalid DWORD count = 0 Running disparity error count = 0 Loss of DWORD synchronization = 0 Phy reset problem = 0 Phy event descriptors: Invalid word count: 0 Running disparity error count: 0 Loss of dword synchronization count: 0 Phy reset problem count: 0 phy identifier = 0 attached device type: no device attached attached reason: unknown reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator port: ssp=0 stp=0 smp=0 attached target port: ssp=0 stp=0 smp=0 SAS address = 0x2 attached SAS address = 0x0 attached phy identifier = 0 Invalid DWORD count = 0 Running disparity error count = 4 Loss of DWORD synchronization = 0 Phy reset problem = 0