smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.8.12-8-pve] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Intel/Solidigm S46x0/S45x0 Series SSDs Device Model: VK000480GWTTA Serial Number: PHYF0040004E480BGN LU WWN Device Id: 5 5cd2e4 1521c15b4 Firmware Version: 4IYRHPG7 User Capacity: 480,103,981,056 bytes [480 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5653 ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Feb 9 14:55:27 2025 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Disabled DSN feature is: Unavailable ATA Security is: Unavailable Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 72) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 3) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SCT capabilities: (0x0021) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0 9 Power_On_Hours -O--CK 100 100 000 - 7641 12 Power_Cycle_Count -O--CK 100 100 000 - 34 170 Available_Reservd_Space PO--CK 100 100 010 - 0 171 Program_Fail_Count -O--CK 100 100 000 - 0 172 Erase_Fail_Count -O--CK 100 100 000 - 0 174 Unsafe_Shutdown_Count -O--CK 100 100 000 - 30 175 Power_Loss_Cap_Test PO--CK 100 100 010 - 2557 (34 65535) 183 SATA_Downshift_Count -O--CK 100 100 000 - 0 184 End-to-End_Error_Count PO--CK 100 100 090 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Drive_Temperature -O---K 083 078 000 - 17 (Min/Max 15/22) 192 Unsafe_Shutdown_Count -O--CK 100 100 000 - 30 194 Temperature_Celsius -O---K 100 100 000 - 17 197 Pending_Sector_Count -O--C- 100 100 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 0 225 Host_Writes_32MiB -O--CK 100 100 000 - 30946 226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 153 227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 86 228 Workload_Minutes -O--CK 100 100 000 - 458134 232 Available_Reservd_Space PO--CK 100 100 010 - 0 233 Media_Wearout_Indicator -O--CK 100 100 000 - 0 234 Thermal_Throttle_Status -O--CK 100 100 000 - 0/0 235 Power_Loss_Cap_Test PO--CK 100 100 010 - 2557 (34 65535) 241 Host_Writes_32MiB -O--CK 100 100 000 - 30946 242 Host_Reads_32MiB -O--CK 100 100 000 - 216170 243 NAND_Writes_32MiB -O--CK 100 100 000 - 99530 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x03 GPL R/O 20 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x07 GPL R/O 2 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x24 GPL R/O 512 Current Device Internal Status Data log 0x25 GPL R/O 512 Saved Device Internal Status Data log 0x30 GPL R/O 9 IDENTIFY DEVICE data log 0x80 GPL R/W 16 Host vendor specific log 0x81-0x9f GPL,SL R/W 16 Host vendor specific log 0xb5 SL VS 1 Device vendor specific log 0xb6 GPL VS 127 Device vendor specific log 0xb8 GPL,SL VS 1 Device vendor specific log 0xb9 GPL VS 3336 Device vendor specific log 0xb9 SL VS 8 Device vendor specific log 0xba GPL VS 1280 Device vendor specific log 0xbb GPL VS 1 Device vendor specific log 0xd0 GPL VS 1 Device vendor specific log 0xd7 GPL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 8 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (20 sectors) No Errors Logged SMART Error Log not supported SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 7499 - SMART Self-test Log not supported SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) Device State: Active (0) Current Temperature: 17 Celsius Power Cycle Min/Max Temperature: 15/22 Celsius Lifetime Min/Max Temperature: 6/23 Celsius Specified Max Operating Temperature: 60 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 00 00 28 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: 0/60 Celsius Temperature History Size (Index): 478 (217) Index Estimated Time Temperature Celsius 218 2025-02-09 06:58 16 - ... ..(417 skipped). .. - 158 2025-02-09 13:56 16 - 159 2025-02-09 13:57 17 - ... ..( 6 skipped). .. - 166 2025-02-09 14:04 17 - 167 2025-02-09 14:05 16 - ... ..( 3 skipped). .. - 171 2025-02-09 14:09 16 - 172 2025-02-09 14:10 17 - 173 2025-02-09 14:11 16 - 174 2025-02-09 14:12 17 - ... ..( 10 skipped). .. - 185 2025-02-09 14:23 17 - 186 2025-02-09 14:24 16 - 187 2025-02-09 14:25 17 - ... ..( 2 skipped). .. - 190 2025-02-09 14:28 17 - 191 2025-02-09 14:29 16 - 192 2025-02-09 14:30 16 - 193 2025-02-09 14:31 16 - 194 2025-02-09 14:32 17 - 195 2025-02-09 14:33 16 - 196 2025-02-09 14:34 17 - ... ..( 20 skipped). .. - 217 2025-02-09 14:55 17 - SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 34 --- Lifetime Power-On Resets 0x01 0x018 6 2028136386 --- Logical Sectors Written 0x01 0x020 6 63604784 --- Number of Write Commands 0x01 0x028 6 14166948009 --- Logical Sectors Read 0x01 0x030 6 59918102 --- Number of Read Commands 0x01 0x038 6 1740666831 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 17 --- Current Temperature 0x05 0x010 1 16 --- Average Short Term Temperature 0x05 0x018 1 16 --- Average Long Term Temperature 0x05 0x020 1 23 --- Highest Temperature 0x05 0x028 1 6 --- Lowest Temperature 0x05 0x030 1 19 --- Highest Average Short Term Temperature 0x05 0x038 1 12 --- Lowest Average Short Term Temperature 0x05 0x040 1 16 --- Highest Average Long Term Temperature 0x05 0x048 1 12 --- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 60 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 45 --- Number of Hardware Resets 0x06 0x010 4 42 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0003 4 0 R_ERR response for device-to-host data FIS 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x0006 4 0 R_ERR response for device-to-host non-data FIS 0x0007 4 0 R_ERR response for host-to-device non-data FIS 0x000a 4 0 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS