smartctl 7.3 2022-02-28 r5338 [x86_64-w64-mingw32-w11-21H2] (sf-7.3-1) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: ASMT109x- Fast Serial Number: S34SJ9FGC00697 LU WWN Device Id: 5 0004cf 2116c59ba Firmware Version: 402220F0 User Capacity: 4,000,797,859,840 bytes [4.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: Not in smartctl database 7.3/5319 ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Fri Apr 01 20:27:21 2022 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (22320) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 372) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 051 - 0 2 Throughput_Performance -OS--K 252 252 000 - 0 3 Spin_Up_Time PO---K 087 083 025 - 4083 4 Start_Stop_Count -O--CK 033 033 000 - 67762 5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0 7 Seek_Error_Rate -OSR-K 252 252 051 - 0 8 Seek_Time_Performance --S--K 252 252 015 - 0 9 Power_On_Hours -O--CK 100 100 000 - 3396 10 Spin_Retry_Count -O--CK 252 252 051 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 234 191 G-Sense_Error_Rate -O---K 252 252 000 - 0 192 Power-Off_Retract_Count -O---K 252 252 000 - 0 194 Temperature_Celsius -O---- 064 045 000 - 29 (Min/Max 16/70) 195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0 196 Reallocated_Event_Count -O--CK 252 252 000 - 0 197 Current_Pending_Sector -O--CK 252 252 000 - 0 198 Offline_Uncorrectable ----CK 252 252 000 - 0 199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0 200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 4 223 Load_Retry_Count -O--CK 100 100 000 - 12 225 Load_Cycle_Count -O--CK 088 088 000 - 125659 241 Total_LBAs_Written -O--CK 097 090 000 - 4650233 242 Total_LBAs_Read -O--CK 091 090 000 - 12700056 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error aborted command Read GP Log Directory failed SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x09 SL R/W 1 Selective self-test log 0x80-0x9f SL R/W 16 Host vendor specific log 0xc0-0xdf SL VS 16 Device vendor specific log 0xe0 SL R/W 1 SCT Command/Status 0xe1 SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported Read SMART Error Log failed: SAT command failed SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 3396 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 31 Celsius Power Cycle Min/Max Temperature: 25/31 Celsius Lifetime Min/Max Temperature: 19/70 Celsius Specified Max Operating Temperature: 80 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 5 minutes Temperature Logging Interval: 5 minutes Min/Max recommended Temperature: -5/80 Celsius Min/Max Temperature Limit: -10/85 Celsius Temperature History Size (Index): 128 (100) Index Estimated Time Temperature Celsius 101 2022-04-01 09:50 31 ************ 102 2022-04-01 09:55 38 ******************* ... ..( 6 skipped). .. ******************* 109 2022-04-01 10:30 38 ******************* 110 2022-04-01 10:35 39 ******************** 111 2022-04-01 10:40 38 ******************* ... ..( 6 skipped). .. ******************* 118 2022-04-01 11:15 38 ******************* 119 2022-04-01 11:20 37 ****************** ... ..( 7 skipped). .. ****************** 127 2022-04-01 12:00 37 ****************** 0 2022-04-01 12:05 38 ******************* ... ..( 48 skipped). .. ******************* 49 2022-04-01 16:10 38 ******************* 50 2022-04-01 16:15 33 ************** 51 2022-04-01 16:20 34 *************** 52 2022-04-01 16:25 36 ***************** 53 2022-04-01 16:30 36 ***************** 54 2022-04-01 16:35 37 ****************** 55 2022-04-01 16:40 37 ****************** 56 2022-04-01 16:45 37 ****************** 57 2022-04-01 16:50 38 ******************* ... ..( 5 skipped). .. ******************* 63 2022-04-01 17:20 38 ******************* 64 2022-04-01 17:25 39 ******************** 65 2022-04-01 17:30 38 ******************* 66 2022-04-01 17:35 38 ******************* 67 2022-04-01 17:40 39 ******************** ... ..( 28 skipped). .. ******************** 96 2022-04-01 20:05 39 ******************** 97 2022-04-01 20:10 32 ************* 98 2022-04-01 20:15 35 **************** 99 2022-04-01 20:20 38 ******************* 100 2022-04-01 20:25 39 ******************** Write SCT (Get) Error Recovery Control Command failed: scsi error aborted command SCT (Get) Error Recovery Control command failed Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) not supported