-------------------------------------------------------------------------------- root@debian:~# fdisk -lu /dev/sda Disk /dev/sda: 465.8 GiB, 500106780160 bytes, 976771055 sectors Units: sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disklabel type: dos Disk identifier: 0x5a5f4a0d Device Boot Start End Sectors Size Id Type /dev/sda1 * 2048 1431551 1429504 698M 7 HPFS/NTFS/exFAT /dev/sda2 43046976 552500046 509453071 242.9G 7 HPFS/NTFS/exFAT /dev/sda3 552501248 553644031 1142784 558M 27 Hidden NTFS WinRE /dev/sda4 553650176 976764927 423114752 201.8G 7 HPFS/NTFS/exFAT -------------------------------------------------------------------------------- smartctl 6.4 2014-10-07 r4002 [i686-linux-3.16.0-4-586] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.11 Device Model: ST3500320AS Serial Number: 9QM7K500 LU WWN Device Id: 5 000c50 0105b787d Firmware Version: SD1A User Capacity: 500,106,780,160 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sat Feb 12 13:38:42 2022 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: ( 634) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 118) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103b) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 119 091 006 Pre-fail Always - 216491860 3 Spin_Up_Time 0x0003 095 094 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 097 097 020 Old_age Always - 3238 5 Reallocated_Sector_Ct 0x0033 094 094 036 Pre-fail Always - 133 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 642560637 9 Power_On_Hours 0x0032 079 079 000 Old_age Always - 18609 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 4 12 Power_Cycle_Count 0x0032 098 098 020 Old_age Always - 3041 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 248 188 Command_Timeout 0x0032 100 098 000 Old_age Always - 25770197043 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 060 055 045 Old_age Always - 40 (Min/Max 39/40) 194 Temperature_Celsius 0x0022 040 045 000 Old_age Always - 40 (0 8 0 0 0) 195 Hardware_ECC_Recovered 0x001a 041 033 000 Old_age Always - 216491860 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 27 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 27 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 53 SMART Error Log Version: 1 ATA Error Count: 248 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 248 occurred at disk power-on lifetime: 18290 hours (762 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 2e 3c 8c 00 Error: WP at LBA = 0x008c3c2e = 9190446 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 61 00 08 ff ff ff 4f 00 00:37:12.405 WRITE FPDMA QUEUED 61 00 40 30 9c cf 4d 00 00:37:12.403 WRITE FPDMA QUEUED 61 00 08 ff ff ff 4f 00 00:37:12.403 WRITE FPDMA QUEUED 60 00 08 28 3c 8c 40 00 00:37:12.402 READ FPDMA QUEUED 61 00 10 ff ff ff 4f 00 00:37:12.401 WRITE FPDMA QUEUED Error 247 occurred at disk power-on lifetime: 18290 hours (762 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 2e 3c 8c 00 Error: UNC at LBA = 0x008c3c2e = 9190446 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 90 ff ff ff 4f 00 00:37:08.552 READ FPDMA QUEUED 60 00 18 ff ff ff 4f 00 00:37:08.552 READ FPDMA QUEUED 60 00 00 ff ff ff 4f 00 00:37:08.552 READ FPDMA QUEUED 60 00 00 ff ff ff 4f 00 00:37:08.551 READ FPDMA QUEUED 60 00 00 ff ff ff 4f 00 00:37:08.551 READ FPDMA QUEUED Error 246 occurred at disk power-on lifetime: 18290 hours (762 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 61 3c 8c 00 Error: UNC at LBA = 0x008c3c61 = 9190497 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 80 88 3c 8c 40 00 00:36:48.591 READ FPDMA QUEUED 61 00 10 ff ff ff 4f 00 00:36:47.476 WRITE FPDMA QUEUED 60 00 80 08 3c 8c 40 00 00:36:47.476 READ FPDMA QUEUED 60 00 80 88 3b 8c 40 00 00:36:47.475 READ FPDMA QUEUED 61 00 10 ff ff ff 4f 00 00:36:47.457 WRITE FPDMA QUEUED Error 245 occurred at disk power-on lifetime: 18283 hours (761 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 c3 69 81 00 Error: UNC at LBA = 0x008169c3 = 8481219 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 00 00 5d 81 40 00 01:37:11.409 READ FPDMA QUEUED 60 00 00 00 56 81 40 00 01:37:11.026 READ FPDMA QUEUED 60 00 00 00 4f 81 40 00 01:37:10.713 READ FPDMA QUEUED 60 00 00 00 4e 81 40 00 01:37:10.713 READ FPDMA QUEUED 60 00 00 00 4d 81 40 00 01:37:10.713 READ FPDMA QUEUED Error 244 occurred at disk power-on lifetime: 18282 hours (761 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ae e8 1d 00 Error: UNC at LBA = 0x001de8ae = 1960110 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 00 00 df 15 40 00 00:34:52.481 READ FPDMA QUEUED 60 00 00 00 de 15 40 00 00:34:52.481 READ FPDMA QUEUED 60 00 00 00 dd 15 40 00 00:34:52.481 READ FPDMA QUEUED 60 00 00 00 dc 15 40 00 00:34:52.480 READ FPDMA QUEUED 60 00 00 00 db 15 40 00 00:34:52.480 READ FPDMA QUEUED -------------------------------------------------------------------------------- SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 00% 18606 - # 2 Short offline Completed: electrical failure 90% 18286 0 # 3 Short offline Completed: electrical failure 90% 18284 0 # 4 Short offline Completed: electrical failure 90% 18284 0 # 5 Short offline Completed: electrical failure 90% 18283 0 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. -------------------------------------------------------------------------------- SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: read failure 90% 18609 335888 # 2 Short offline Interrupted (host reset) 00% 18606 - # 3 Short offline Completed: electrical failure 90% 18286 0 # 4 Short offline Completed: electrical failure 90% 18284 0 # 5 Short offline Completed: electrical failure 90% 18284 0 # 6 Short offline Completed: electrical failure 90% 18283 0 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.