smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.43-1-lts] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: INTEL SSDSC2BF240A5L Firmware Version: LT2i User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 (minor revision not indicated) SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Jan 30 15:15:18 2021 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x05) Offline data collection activity was aborted by an interrupting command from host. Auto Offline Data Collection: Disabled. Self-test execution status: ( 16) The self-test routine was aborted by the host. Total time to complete Offline data collection: ( 5860) seconds. Offline data collection capabilities: (0x7f) SMART execute Offline immediate. Auto Offline data collection on/off support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 58) minutes. Conveyance self-test routine recommended polling time: ( 4) minutes. SCT capabilities: (0x0025) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct -O--CK 100 100 000 - 1 9 Power_On_Hours -O--CK 100 100 000 - 1796 12 Power_Cycle_Count -O--CK 100 100 000 - 926 170 Unknown_Attribute PO--CK 098 100 010 - 0 171 Unknown_Attribute -O--CK 100 100 000 - 0 172 Unknown_Attribute -O--CK 100 100 000 - 0 174 Unknown_Attribute -O--CK 100 100 000 - 31 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 100 100 090 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 030 100 000 - 30 (Min/Max 12/67) 192 Power-Off_Retract_Count -O--CK 100 100 000 - 31 194 Temperature_Celsius -O--CK 030 100 000 - 30 (Min/Max 12/67) 199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0 225 Unknown_SSD_Attribute -O--CK 100 100 000 - 196617 226 Unknown_SSD_Attribute -O--CK 100 100 000 - 65535 227 Unknown_SSD_Attribute -O--CK 100 100 000 - 52 228 Power-off_Retract_Count -O--CK 100 100 000 - 65535 232 Available_Reservd_Space PO--CK 098 100 010 - 0 233 Media_Wearout_Indicator -O--CK 092 100 000 - 0 241 Total_LBAs_Written -O--CK 100 100 000 - 196617 242 Total_LBAs_Read -O--CK 100 100 000 - 211435 249 Unknown_Attribute -O--CK 100 100 000 - 43345 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 0 SMART Log Directory Version 0 Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test Log not supported SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 0 (0x0000) Device State: Active (0) Current Temperature: 30 Celsius Power Cycle Min/Max Temperature: 12/67 Celsius Lifetime Min/Max Temperature: 12/77 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 0 (Unknown, should be 2) Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/ 0 Celsius Min/Max Temperature Limit: 0/ 0 Celsius Temperature History Size (Index): 0 (141) Temperature History is empty SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC 0x0002 2 0 R_ERR response for data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS