smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.3.18-lp152.41-default] (SUSE RPM) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Seagate BarraCuda 120 SSD ZA1000CM10003 Serial Number: 7QW01EF7 LU WWN Device Id: 5 000c50 0bb1e14ee Firmware Version: STRSD013 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Sep 21 07:48:03 2020 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 30) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0 9 Power_On_Hours -O--C- 100 100 000 - 67 12 Power_Cycle_Count -O--C- 100 100 000 - 77 16 Unknown_Attribute -O--C- 100 100 000 - 2286 17 Unknown_Attribute -O--C- 100 100 000 - 2286 168 Unknown_Attribute -O--C- 100 100 000 - 0 170 Unknown_Attribute PO---- 100 100 010 - 453 173 Unknown_Attribute -O--C- 100 100 000 - 4295163909 174 Unknown_Attribute -O--C- 100 100 000 - 66 177 Wear_Leveling_Count ------ 100 100 000 - 0 192 Power-Off_Retract_Count -O--C- 100 100 000 - 66 194 Temperature_Celsius PO---K 102 091 000 - 25 (Min/Max 20/36) 218 Unknown_Attribute PO-R-- 100 100 050 - 0 231 Unknown_SSD_Attribute PO--C- 100 100 000 - 99 232 Available_Reservd_Space PO--C- 100 100 000 - 0 233 Media_Wearout_Indicator PO-R-- 100 100 000 - 1739 235 Unknown_Attribute PO-R-- 100 100 000 - 3647424640 241 Total_LBAs_Written -O--C- 100 100 000 - 1234 242 Total_LBAs_Read -O--C- 100 100 000 - 280 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 51 Comprehensive SMART error log 0x03 GPL R/O 64 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xc1 GPL VS 32760 Device vendor specific log 0xc2 GPL VS 8 Device vendor specific log 0xc3-0xcb GPL VS 32760 Device vendor specific log 0xdc GPL VS 16 Device vendor specific log 0xdf GPL VS 32760 Device vendor specific log SMART Extended Comprehensive Error Log Version: 1 (64 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 0 - # 2 Short offline Completed without error 00% 0 - # 3 Short offline Completed without error 00% 0 - # 4 Short offline Completed without error 00% 0 - # 5 Extended offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 77 --- Lifetime Power-On Resets 0x01 0x010 4 67 --- Power-on Hours 0x01 0x018 6 2589147700 --- Logical Sectors Written 0x01 0x020 6 8609646935 --- Number of Write Commands 0x01 0x028 6 589025644 --- Logical Sectors Read 0x01 0x030 6 8598133544 --- Number of Read Commands 0x01 0x038 6 242009616 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 25 --- Current Temperature 0x05 0x010 1 - --- Average Short Term Temperature 0x05 0x018 1 - --- Average Long Term Temperature 0x05 0x020 1 36 --- Highest Temperature 0x05 0x028 1 20 --- Lowest Temperature 0x05 0x030 1 - --- Highest Average Short Term Temperature 0x05 0x038 1 - --- Lowest Average Short Term Temperature 0x05 0x040 1 - --- Highest Average Long Term Temperature 0x05 0x048 1 - --- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 225 --- Number of Hardware Resets 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 1 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 2 Device-to-host register FISes sent due to a COMRESET 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC