smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.10.0-42-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Ultrastar A7K1000 Device Model: HITACHI HUA721075KLA330 Serial Number: P8H91GWF LU WWN Device Id: 5 000cca 215d23466 Firmware Version: GK8OA90A User Capacity: 750,156,374,016 bytes [750 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 T13/1532D revision 1 Local Time is: Sun Oct 27 12:07:01 2019 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 128 (quiet), recommended: 128 APM level is: 1 (minimum power consumption with standby) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x04) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (11471) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 191) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance P-S--- 130 130 054 - 150 3 Spin_Up_Time POS--- 108 108 024 - 551 (Average 554) 4 Start_Stop_Count -O--C- 100 100 000 - 277 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 134 134 020 - 32 9 Power_On_Hours -O--C- 100 100 000 - 312 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 145 192 Power-Off_Retract_Count -O--CK 100 100 000 - 282 193 Load_Cycle_Count -O--C- 100 100 000 - 282 194 Temperature_Celsius -O---- 250 250 000 - 24 (Min/Max 15/56) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x24 GPL R/O 60 Current Device Internal Status Data log 0x80 GPL R/W 60 Host vendor specific log 0x81-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Aborted by host 10% 1 - # 2 Short offline Completed without error 00% 63597 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 24 Celsius Power Cycle Max Temperature: 38 Celsius Lifetime Max Temperature: 56 Celsius SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 5/60 Celsius Min/Max Temperature Limit: -40/65 Celsius Temperature History Size (Index): 128 (113) Index Estimated Time Temperature Celsius 114 2019-10-27 10:00 25 ****** ... ..( 20 skipped). .. ****** 7 2019-10-27 10:21 25 ****** 8 2019-10-27 10:22 24 ***** 9 2019-10-27 10:23 25 ****** 10 2019-10-27 10:24 24 ***** ... ..(102 skipped). .. ***** 113 2019-10-27 12:07 24 ***** SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS