#1678 attribute spelling is inconsistent between different drivedb entries defect minor unscheduled drivedb
#1504 defect - WD Elements external hard drive errors with "not capable of SMART self-check" defect major undecided all
#1456 disk is missed in database (TOSHIBA-VT180) enhancement minor unscheduled drivedb
#1798 drivedb.h: Seagate IronWolf Pro RegEx Improvement enhancement minor unscheduled drivedb
#1527 linux megaraid: opening the device for ioctls with O_RDWR causes a partition rescan patch major undecided all
#1643 missing from database: INTEL SSDSC2BF180A5L enhancement minor unscheduled drivedb
#920 need to help for some correction : PM871b HP defect minor unscheduled drivedb
#1431 new hdd for database - IBM-Seagate-ST33000650NS enhancement minor unscheduled drivedb
#964 new re-RMA disk, smartmontools shows Power-off_retract_count > 65536+ but other 'Count' values are < 5-10 enhancement minor undecided drivedb
#1639 no description for -d nvme in smartd.conf defect minor unscheduled smartd
#1061 not in smartctl database: TOSHIBA HDWA120 enhancement minor unscheduled drivedb
#52 os_linux.cpp: Implement linux_highpoint_device::ata_pass_through() somebody enhancement major unscheduled all
#105 os_qnxnto.cpp: Migrate to new dev_interface somebody enhancement major unscheduled all
#690 os_solaris.cpp: Add NVMe support for Solaris and IllumOS enhancement minor undecided all
#104 os_solaris.cpp: Migrate to new dev_interface somebody enhancement major unscheduled all
#1743 please add -d sat for Sandisk SDSSDE30-2T00 enhancement minor unscheduled drivedb
#1814 please add support for Micron CT1000X9SSD9 (0x0634:0x5605) enhancement minor undecided drivedb
#1193 report for KINGSTON SM2280S3120G (M.2) enhancement minor unscheduled all
#1779 set smartd.conf settings based on type, manufacturer, model enhancement minor undecided smartd
#1773 smartctl --scan can not detect the disks behind a megaraid controller on Dell Poweredge R620 with windows os enhancement minor undecided all
#1496 smartctl -s standby,now SPINS up other drives! (Windows) defect minor undecided smartctl
#1625 smartctl does not check physical element status defect minor undecided smartctl
#1568 smartctl messages ‘Error: UNC at LBA’ invalid value for Windows defect minor undecided smartctl
#1641 smartctl.exe -d aacraid on Windows crashing when called with full path to binary defect major undecided all
#1623 smartd SMART Failure events even after the HDD is replaced defect major undecided smartd
#1190 smartd not writing attributes (-A) for NVMe devices enhancement minor unscheduled smartd
#1505 smartd: only start self-test if temperature is low enough? enhancement minor undecided smartd
#1670 smartd: per device rules don't match for nvmes defect minor undecided smartd