Custom Query (1265 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (22 - 24 of 1265)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Ticket Resolution Summary Owner Reporter
#285 wontfix unsupported highpoint rocketraid 3520 somebody grimlokason
Description

Hello,

smartctl seem to don't recognize my controler :

abyss raspi # smartctl -a -d hpt,1/1/1 /dev/sda
smartctl 6.1 2013-03-16 r3800 [x86_64-linux-3.6.6-gentoo] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

Read Device Identity failed: Invalid argument

A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.


In doubt, i've tryed with various combination for the hpt,L/M/N without succes.

Some other information :

abyss raspi # smartctl -a /dev/sda
smartctl 6.1 2013-03-16 r3800 [x86_64-linux-3.6.6-gentoo] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Vendor:               HPT
Product:              VD0-0
Revision:             4.00
User Capacity:        9 001 513 254 912 bytes [9,00 TB]
Logical block size:   4096 bytes
Logical Unit id:      0x00193c0000000000
Serial number:
Device type:          disk
Local Time is:        Wed Jul  3 21:24:55 2013 CEST
SMART support is:     Unavailable - device lacks SMART capability.

=== START OF READ SMART DATA SECTION ===

Error Counter logging not supported

When i used the htp's cli tool i can get smart information :

HighPoint CLI>query devices 1/1
Mode Number:        WDC WD30EFRX-68AX9N0
Serial Number:           WD-WMC1T0854995
Firmware Version:   80.00A80
Capacity(GB):   3000.50             TotalFree(GB):  0
Status:         RAID                Flag:           NORMAL
Read Ahead:     enabled             Write Cache:    enabled
TCQ:            --                  NCQ:            enabled
-------------------------------------------------------------------------------
                                S.M.A.R.T Attributes
Status: S.M.A.R.T OK.
ID  Name                           Threshold  Value      Worst      Status
-------------------------------------------------------------------------------
1   Raw Read Error Rate            51         200        200        OK
3   Spin Up Time                   21         180        172        OK
4   Start Stop Count               0          100        100        OK
5   Reallocated Sector Ct          140        200        200        OK
7   Seek Error Rate                0          200        200        OK
9   Power On Hours                 0          93         93         OK
A   Spin Retry Count               0          100        100        OK
B   Calibration Retry Count        0          100        100        OK
C   Power Cycle Count              0          100        100        OK
C0  Power-Off Retract Count        0          200        200        OK
C1  Emergency Retract Cycle Ct     0          200        200        OK
C2  Temperature Celsius            0          125        98         OK
C4  Reallocated Event Count        0          200        200        OK
C5  Current Pending Sector         0          200        200        OK
C6  Offline Uncorrectable          0          100        253        OK
C7  UDMA CRC Error Count           0          200        200        OK
C8  Multi Zone Error Rate          0          100        253        OK
-------------------------------------------------------------------------------

Can someone help me to get this controler supported ?

Regards

#160 wontfix trivial: switch CL CH to CH CL somebody dg12
Description

First thanks for a great tool.

This is a real trivial request: could the output for CH CL be switched in these (and any other displays). And could the SN be positioned to the right of DH

Commands leading to the command that caused the error were:

CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 08 70 31 a1 40 00 04:08:14.561 READ DMA EXT

After command completion occurred, registers were:

ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 70 31 a1 43 Error: UNC 8 sectors at LBA = 0x03a13170 = 60895600

#519 invalid testing new trac, plz ignore Alex Samorukov