Custom Query (1359 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (100 - 102 of 1359)

Ticket Resolution Summary Owner Reporter
#150 fixed Adding scterc set command to smartd Christian Franke art9
Description

Please add scterc set command to smartd if possible

#151 fixed Report working USB bridge manfred99 jlivdahl
Description

I would like to report that this Unknown USB bridge [0x0bc2:0x50a1]

Work with: -d sat,12

It is the Seagate FreeAgent GoFlex Desk USB 3.0 external HDD Tested with Windows 7 x64 with a Gigabyte GA-H55M-USB motherboard

#153 fixed missing USB bridge for LaCie Drive Christian Franke thomasvs
Description

[root@davedina ~]# smartctl --all /dev/sde -d auto smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

/dev/sde: Unknown USB bridge [0x059f:0x1029 (0x100)] Smartctl: please specify device type with the -d option.

Use smartctl -h to get a usage summary

[root@davedina ~]# smartctl --all /dev/sde -d sat smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

START OF INFORMATION SECTION

Model Family: Hitachi Deskstar 7K2000 Device Model: Hitachi HDS722020ALA330 Serial Number: JK1121YAG4220S Firmware Version: JKAOA10D User Capacity: 2,000,398,934,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Fri Mar 4 16:45:52 2011 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values: Offline data collection status: (0x84) Offline data collection activity

was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever been run.

Total time to complete Offline data collection: (22036) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate.

Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode. Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 255) minutes. SCT capabilities: (0x003d) SCT Status supported.

SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported.

SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 134 134 054 Pre-fail Offline - 97 3 Spin_Up_Time 0x0007 114 114 024 Pre-fail Always - 632 (Average 635) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 56 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 1 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 112 112 020 Pre-fail Offline - 39 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 1595

10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 53

192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 56 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 56 194 Temperature_Celsius 0x0002 253 253 000 Old_age Always - 21 (Min/Max 17/58) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0

SMART Error Log Version: 0 No Errors Logged

SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.

Works with SAT, so I think you can add it safely.

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.