#636 fixed Add SAMSUNG MZ7LN128HCHP-00000 spacedust
Description

Please add SAMSUNG MZ7LN128HCHP-00000 to the database.

It seems to be Samsung PM-871

smartctl 6.5 2016-01-06 r4198 [x86_64-linux-4.4.0-1.el6.elrepo.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG MZ7LN128HCHP-00000
Serial Number:    S1ZFNXAG701382
LU WWN Device Id: 5 002538 d402b799b
Firmware Version: EMT0100Q
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sun Jan 17 17:27:03 2016 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x53) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  64) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       49
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       3
170 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   010    Old_age   Always       -       0
173 Unknown_Attribute       0x0033   099   099   005    Pre-fail  Always       -       1
174 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       -       1
178 Used_Rsvd_Blk_Cnt_Chip  0x0013   100   100   010    Pre-fail  Always       -       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0013   100   100   010    Pre-fail  Always       -       386
184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0032   063   056   000    Old_age   Always       -       37
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       -       0
233 Media_Wearout_Indicator 0x0013   099   099   000    Pre-fail  Always       -       16768826
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       -       123
242 Total_LBAs_Read         0x0032   099   099   000    Old_age   Always       -       114
249 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       -       128

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
#1811 duplicate Add SK hynix SE5110 to the Database (Same request as #1776) ksj0312
Description

Hi

I wrote #1776 request because I think I need to update the drive database. However, even after 3 months of requesting #1776 cases, there is no update in the drive database, so I'm requesting it again. There are a total of four drives that need to be registered, and I have attached this information as a file, so please register as soon as possible.

Thank you.

#1104 duplicate Add SSD Samsung 860 Pro 1TB in smartcl database IT-PTT-Support
Description

Hello,

i would like to share report of SSD Samsung 860 Pro 1TB in order to add it in your database.

Thanks,

Prisma Telecom Testing

Batch Modify