#253 wontfix Add Highpoint RocketRAID support (hptiop) Alex Samorukov noobsauce80
Description

I mainly work with FreeNAS systems, but I found an issue that I think can be resolved here.

I have a RocketRAID 4520 controller(latest generation from Highpoint). When I use the command smartctl -a -d hpt,1/1/1 /dev/hptiop0 I get the error "Smartctl: Device Read Identity Failed: Bad address'.

It appears that this issue was previously documented in ticket:71. That ticket was closed since nobody had this controller. I have a controller from each of the 35xx, 43xx, and 45xx family of controllers. AFAIK the only way to get any SMART data and run any tests is via the Highpoint CLI available as a binary only. My guess is that all 3 families of controller mentioned above and the 44xx will all work with the same appropriate fix.

I have a system that I can give SSH and FTP access to on request. I only have the 45xx until the end of the year however(on loan to help facilitate support for FreeNAS).

You can read additional information on this issue provided by me at the FreeNAS ticket https://support.freenas.org/ticket/1932.

I listed the priority as major since so many generations of cards are included with this ticket.

#1234 fixed Add Infos for ICY BOX IB-RD2253-U31 in drivedb.h (0x1234:0x5678) Christian Franke Daniel P
Description

This adds info for the 2bay 2.5" external RAID enclosure icybox, using a Brain Actuated Technologies usb chip with id 0x1234:0x5678.

Works fine with "-d sat,12"

#713 fixed Add Innodisk Mini PCIeDOM 1ME3 to the drive database Christian Franke manrud
Description
smartctl 6.5 2016-05-07 r4318 [ppc-linux-3.2.78-rt113] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     Mini PCIeDOM 1ME3
Serial Number:    20151006AA1858000001
LU WWN Device Id: 5 24693e 2015a0001
Firmware Version: S15604
User Capacity:    64,023,257,088 bytes [64.0 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 3.0, 1.5 Gb/s (current: 1.5 Gb/s)
Local Time is:    Mon Jan  3 19:25:53 2000 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Read SCT Status failed: scsi error aborted command
Wt Cache Reorder: Unknown (SCT Feature Control command failed)

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection:                (   32) seconds.
Offline data collection
capabilities:                    (0x0b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        No Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.
SCT capabilities:              (0x0039) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   000   000   000    -    0
  2 Throughput_Performance  ------   000   000   000    -    0
  3 Spin_Up_Time            ------   000   000   000    -    0
  5 Reallocated_Sector_Ct   -O----   100   100   000    -    0
  7 Unknown_SSD_Attribute   ------   000   000   000    -    0
  8 Unknown_SSD_Attribute   ------   000   000   000    -    0
  9 Power_On_Hours          -O----   100   100   000    -    18
 10 Unknown_SSD_Attribute   ------   000   000   000    -    0
 12 Power_Cycle_Count       -O----   100   100   000    -    33
168 Unknown_Attribute       ------   000   000   000    -    0
169 Unknown_Attribute       ------   099   000   000    -    108851651149824
175 Program_Fail_Count_Chip ------   000   000   000    -    0
192 Power-Off_Retract_Count ------   000   000   000    -    0
194 Temperature_Celsius     ------   030   100   000    -    0 (2 100 0 0 0)
197 Current_Pending_Sector  ------   000   000   000    -    0
240 Unknown_SSD_Attribute   ------   000   182   000    -    335698
225 Unknown_SSD_Attribute   ------   000   000   000    -    0
170 Unknown_Attribute       PO----   000   000   ---    -    2228224
173 Unknown_Attribute       -O--C-   000   000   ---    -    196609
229 Unknown_Attribute       -O----   000   000   ---    -    88470212370072
236 Unknown_Attribute       -O----   000   000   ---    -    0
235 Unknown_Attribute       -O----   000   000   ---    -    0
176 Erase_Fail_Count_Chip   ------   000   000   ---    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed: scsi error aborted command

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error aborted command
Read GP Log Directory failed

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log not supported

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test Log not supported

Selective Self-tests/Logging not supported

Read SCT Status failed: scsi error aborted command

Read SCT Status failed: scsi error aborted command
SCT (Get) Error Recovery Control command failed

Device Statistics (GP/SMART Log 0x04) not supported

ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: scsi error aborted command
Read SATA Phy Event Counters failed