#80 fixed Update information about Transcend SSD Christian Franke gnomeby
Description

Hi, I've downloaded Data sheet (http://www.transcendusa.com/Support/DLCenter/dllogin.asp?Link=dlcenter|Datasheet|SSD25S-JMI Datasheet v2.5.pdf) for some Transcend SSD and would like to submit update for drivedb.

Thanks.

#81 fixed support areca in freebsd Alex Samorukov torgull
Description

hello, linux has full support for areca raid controllers. i'm wondering if its possible for you to add freebsd support too.

#83 fixed iomega LDHD-UP Christian Franke bikepunk2
Description

I just added the Iomega LDHD-UP in the USB supported device list on my own and then I saw that I'm supposed to write to you. Sorry. Hoping I was right

If you're interested here is my smartctl -a -d usbsunplus /dev/sdb :

smartctl 5.39.1 2010-01-28 r3054 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

START OF INFORMATION SECTION

Model Family: Seagate Barracuda 7200.12 family Device Model: ST3500418AS Serial Number: 6VMAG6CM Firmware Version: CC38 User Capacity: 500,107,862,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Wed Jul 7 01:53:05 2010 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values: Offline data collection status: (0x82) Offline data collection activity

was completed without error. Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever been run.

Total time to complete Offline data collection: ( 609) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate.

Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode. Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 91) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103f) SCT Status supported.

SCT Feature Control supported. SCT Data Table supported.

SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x000f 080 080 006 Pre-fail Always - 192598735 3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 134 5 Reallocated_Sector_Ct 0x0033 062 062 036 Pre-fail Always - 1565 7 Seek_Error_Rate 0x000f 100 253 030 Pre-fail Always - 389014 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 355

10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 57

183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 115 188 Command_Timeout 0x0032 100 091 000 Old_age Always - 120260919324 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 061 050 045 Old_age Always - 39 (Lifetime Min/Max 39/43) 194 Temperature_Celsius 0x0022 039 050 000 Old_age Always - 39 (0 16 0 0) 195 Hardware_ECC_Recovered 0x001a 038 030 000 Old_age Always - 192598735 197 Current_Pending_Sector 0x0012 040 040 000 Old_age Always - 2470 198 Offline_Uncorrectable 0x0010 040 040 000 Old_age Offline - 2470 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 83163451752791 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 3915841531 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 857597085

SMART Error Log Version: 1 ATA Error Count: 64239 (device log contains only the most recent five errors)

CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX]

Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 64239 occurred at disk power-on lifetime: 349 hours (14 days + 13 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 71 04 9d 00 32 40 Device Fault; Error: ABRT 4 sectors at LBA = 0x0032009d = 3276957

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 03 08 20 45 69 40 00 03:21:55.134 READ DMA EXT 25 03 08 20 45 69 40 00 03:21:55.104 READ DMA EXT 25 03 80 20 45 69 40 00 03:21:55.073 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:55.042 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:55.011 READ DMA EXT

Error 64238 occurred at disk power-on lifetime: 349 hours (14 days + 13 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 71 04 9d 00 32 40 Device Fault; Error: ABRT 4 sectors at LBA = 0x0032009d = 3276957

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 03 08 20 45 69 40 00 03:21:55.104 READ DMA EXT 25 03 80 20 45 69 40 00 03:21:55.073 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:55.042 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:55.011 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:54.981 READ DMA EXT

Error 64237 occurred at disk power-on lifetime: 349 hours (14 days + 13 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 71 04 9d 00 32 40 Device Fault; Error: ABRT 4 sectors at LBA = 0x0032009d = 3276957

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 03 80 20 45 69 40 00 03:21:55.073 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:55.042 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:55.011 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:54.981 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:54.951 READ DMA EXT

Error 64236 occurred at disk power-on lifetime: 349 hours (14 days + 13 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 71 04 9d 00 32 40 Device Fault; Error: ABRT 4 sectors at LBA = 0x0032009d = 3276957

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 03 08 18 45 69 40 00 03:21:55.042 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:55.011 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:54.981 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:54.951 READ DMA EXT 25 03 08 10 45 69 40 00 03:21:54.921 READ DMA EXT

Error 64235 occurred at disk power-on lifetime: 349 hours (14 days + 13 hours)

When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 71 04 9d 00 32 40 Device Fault; Error: ABRT 4 sectors at LBA = 0x0032009d = 3276957

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 03 08 18 45 69 40 00 03:21:55.011 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:54.981 READ DMA EXT 25 03 08 18 45 69 40 00 03:21:54.951 READ DMA EXT 25 03 08 10 45 69 40 00 03:21:54.921 READ DMA EXT 25 03 08 10 45 69 40 00 03:21:54.890 READ DMA EXT

SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.