Custom Query (1552 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (292 - 294 of 1552)

Ticket Resolution Summary Owner Reporter
#1569 fixed add to drivedb: Sandisk SD9SN8W (SD9SN8W128G1020) Gabriele Pohl Vadmin
Description

Could you add the following disk reference in the smartctl database ? Here is the smartctl -a output:

=== START OF INFORMATION SECTION ===
Device Model:     SanDisk SD9SN8W128G1020
Serial Number:    ....
LU WWN Device Id: 5 001b44 8b994b732
Firmware Version: X6101020
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      M.2
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is:  SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Feb 15 01:21:47 2022 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever
					been run.
Total time to complete Offline
data collection: 		(    0) seconds.
Offline data collection
capabilities: 			 (0x11) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					No Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  10) minutes.

SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0032   100   100   ---    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   ---    Old_age   Always       -       26536
 12 Power_Cycle_Count       0x0032   100   100   ---    Old_age   Always       -       25
165 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       1356418753
166 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       104
167 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       34
168 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       172
169 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       102
170 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
173 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       145
174 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       5
184 End-to-End_Error        0x0032   100   100   ---    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   ---    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   ---    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   064   070   ---    Old_age   Always       -       36 (Min/Max 27/70)
199 UDMA_CRC_Error_Count    0x0032   100   100   ---    Old_age   Always       -       0
230 Unknown_SSD_Attribute   0x0032   100   100   ---    Old_age   Always       -       44118142232608
232 Available_Reservd_Space 0x0033   100   100   004    Pre-fail  Always       -       100
233 Media_Wearout_Indicator 0x0032   100   100   ---    Old_age   Always       -       18443
234 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       56778
241 Total_LBAs_Written      0x0030   253   253   ---    Old_age   Offline      -       40598
242 Total_LBAs_Read         0x0030   253   253   ---    Old_age   Offline      -       39691
244 Unknown_Attribute       0x0032   000   100   ---    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported
#1112 fixed add to drivedb: Sandisk SD9SB8W (128G1122 / 512G-1006 / 256G-1122 / 1T-1122) jeremy385892a
Description

Could you add the following disk reference in the smartctl database ?

Here is the smartctl -a output:

>smartctl -a /dev/ada0
smartctl 6.3 2014-07-26 r3976 [NS-BSD 2.7.2- amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SanDisk SD9SB8W128G1122
Serial Number:    174970801128
LU WWN Device Id: 5 001b44 8b688bbc1
Firmware Version: X6104000
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   Unknown(0x0ff0) (unknown minor revision code: 0x005e)
SATA Version is:  SATA >3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Oct 19 08:23:03 2018 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x11) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.

SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0032   100   100   ---    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   ---    Old_age   Always       -       362
 12 Power_Cycle_Count       0x0032   100   100   ---    Old_age   Always       -       7
165 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       65536
166 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
167 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       23
168 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
169 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       78
170 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
173 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
174 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       4
184 End-to-End_Error        0x0032   100   100   ---    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   ---    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   ---    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   072   041   ---    Old_age   Always       -       28 (Min/Max 25/41)
199 UDMA_CRC_Error_Count    0x0032   100   100   ---    Old_age   Always       -       0
230 Unknown_SSD_Attribute   0x0032   100   100   ---    Old_age   Always       -       0
232 Available_Reservd_Space 0x0033   100   100   004    Pre-fail  Always       -       100
233 Media_Wearout_Indicator 0x0032   100   100   ---    Old_age   Always       -       0
234 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       1
241 Total_LBAs_Written      0x0030   253   253   ---    Old_age   Offline      -       1
242 Total_LBAs_Read         0x0030   253   253   ---    Old_age   Offline      -       0
244 Unknown_Attribute       0x0032   000   100   ---    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported

Many thanks

#1120 fixed add to drivedb: SanDisk SSD PLUS 120 GB Christian Franke Gabriele Pohl
Description

Bjarne Schmidt reported via database mailing list:

smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.13.9-300.fc27.x86_64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

START OF INFORMATION SECTION

Device Model: SanDisk SSD PLUS 120 GB Firmware Version: UE3000RL User Capacity: 120.040.980.480 bytes [120 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall]

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.