| #250 | fixed | implement -g/-s wcache and lookahead for the SCSI drvies | ||
| Description |
Most of SCSI/SAS drives are supporting cache control, so it is possible to implement this functionality. This should help a lot for SAS drives behind the RAID - some of them turning off write cache if drive is not "native". Tested on scsi, megaraid and cciss device types on Linux. It was found that cciss silently filtering MODE SELECT command, so actual values are not changed. On megaraid and direct connection everything works as expected. |
|||
| #1516 | duplicate | hp array (CCISS) support for windows | ||
| Description |
CCISS (HP/Compaq Smart Array Controller) is not supported, is there any way to add support for windows? |
|||
| #850 | invalid | how to setup disk failure alerts notification to email in centos 7.3 | ||
| Description |
how to setup disk failure alerts notification to email in centos 7.3 The requirement is i should i get email notification if some disk's failed on the server. Now its very difficult to get to know some disk's are failed in the server. Could you please help on this, I am new to smartctl |
|||