Custom Query (1556 matches)
Results (358 - 360 of 1556)
| Ticket | Resolution | Summary | Owner | Reporter |
|---|---|---|---|---|
| #906 | duplicate | add drive to database: WD WDBCKA0080HBK-NESN | ||
| Description |
I have the following drive that is not in the database. When I try to monitor this drive, I get errors (tried 2 different models of this drive, and both error) when attempting to monitor the drive with offline SMART checks. I receive these errors on the drives when attempting to do offline SMART checks: FailedReadSmartData FailedHealthCheck All tests of the drive pass. |
|||
| #1393 | fixed | add drive to database: SMART Modular SVM2S46128GNPI51UF | ||
| #252 | fixed | add disks on megaraid sas controller to DEVICESCAN | ||
| Description |
I decided to add autoscan functionality for drives on MegaSAS controllers. Main motivation for this was that devices on such controllers having random numbers, from 0 to ~250 and it is very annoying to write smartd configuration (i used shell + MegaCli in the past). There is no ioctl documentation provided, so i did patch based on MegaCli tool behavior (with strace and LD_PRELAOD for IOCTL) and FreeBSD driver sources which contain similar code. What this patch is doing:
Code changes:
Example: [root@p2986890 smartmontools]# ./smartctl --scan /dev/sda -d scsi # /dev/sda, SCSI device /dev/bus/0 -d megaraid,5 # /dev/bus/0 [megaraid_disk_05], SCSI device /dev/bus/0 -d megaraid,7 # /dev/bus/0 [megaraid_disk_07], SCSI device [root@p2986890 smartmontools]# ./smartctl --scan-open # /dev/sda -d scsi # /dev/sda, SCSI device open failed: DELL or MegaRaid controller, please try adding '-d megaraid,N' /dev/bus/0 -d sat+megaraid,5 # /dev/bus/0 [megaraid_disk_05] [SAT], ATA device /dev/bus/0 -d sat+megaraid,7 # /dev/bus/0 [megaraid_disk_07] [SAT], ATA device [root@p2986890 smartmontools]# ./smartd -d smartd 6.1 2012-12-14 r3732M [x86_64-linux-2.6.32-279.14.1.el6.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org No configuration file /usr/local/etc/smartd.conf found, scanning devices glob(3) found no matches for pattern /dev/hd[a-t] glob(3) found no matches for pattern /dev/sd[a-c][a-z] Device: /dev/sda, open() failed: DELL or MegaRaid controller, please try adding '-d megaraid,N' Device: /dev/bus/0 [megaraid_disk_05], type changed from 'megaraid,5' to 'sat+megaraid,5' Device: /dev/bus/0 [megaraid_disk_05] [SAT], opened Device: /dev/bus/0 [megaraid_disk_05] [SAT], WDC WD1003FBYX-01Y7B1, S/N:WD-XXXX, WWN:XXXX, FW:01.01V02, 1.00 TB Device: /dev/bus/0 [megaraid_disk_05] [SAT], found in smartd database: Western Digital RE4 Serial ATA Device: /dev/bus/0 [megaraid_disk_05] [SAT], not capable of SMART Health Status check Device: /dev/bus/0 [megaraid_disk_05] [SAT], is SMART capable. Adding to "monitor" list. Device: /dev/bus/0 [megaraid_disk_07], type changed from 'megaraid,7' to 'sat+megaraid,7' Device: /dev/bus/0 [megaraid_disk_07] [SAT], opened Device: /dev/bus/0 [megaraid_disk_07] [SAT], WDC WD1003FBYX-01Y7B1, S/N:WD-XXXX, WWN:XXXX, FW:01.01V02, 1.00 TB Device: /dev/bus/0 [megaraid_disk_07] [SAT], found in smartd database: Western Digital RE4 Serial ATA Device: /dev/bus/0 [megaraid_disk_07] [SAT], not capable of SMART Health Status check Device: /dev/bus/0 [megaraid_disk_07] [SAT], is SMART capable. Adding to "monitor" list. Monitoring 2 ATA and 0 SCSI devices Device: /dev/bus/0 [megaraid_disk_05] [SAT], opened ATA device Device: /dev/bus/0 [megaraid_disk_05] [SAT], previous self-test completed without error Device: /dev/bus/0 [megaraid_disk_07] [SAT], opened ATA device Device: /dev/bus/0 [megaraid_disk_07] [SAT], previous self-test completed without error |
|||
