#954 | fixed | Add support for ADATA SU800 SSDs (128GB, Firmware Q0913A) | ||||||||||||||||||||||||||||||||||||||||||
Description |
Please, add ADATA SU800 SSD devices to smartdb. Capacities are between 128GB and 1TB. Specifications are at http://www.adata.com/us/specification/410 ADATA SMART attributes are described in http://www.adata.com/AppStore/ADATA%20SSD%20Toolbox_UserGuide_V10_EN.pdf |
|||||||||||||||||||||||||||||||||||||||||||
#1221 | fixed | Add support for ASMedia ASM2362 USB to NVMe bridge | ||||||||||||||||||||||||||||||||||||||||||
Description |
ASMedia ASM2362 provides a vendor specific NVMe pass-through SCSI command. This should be supported by smartmontools via a new See also the original report on smartmontools-database list. The commit 6dc489 from CrystalDiskInfo source code (SPDX-License-Identifier: MIT), shows the following CDB settings:
CDW10 = 0x00000001 for Identify Controller CDW10 = 0x007F0002 for Get SMART/Health Log (always 512 bytes) CDW10 = 0x01FF0001 for Get Error Log with 2048 bytes. Assignments of CDW10.byte3 and NSID are not obvious. |
|||||||||||||||||||||||||||||||||||||||||||
#1444 | fixed | Add support for Apacer AS350 |