Custom Query (1384 matches)
Results (136 - 138 of 1384)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#754 | fixed | Add drive to database - Samsung MZNLF128HCHP | ||
Description |
output attached as per FAQ If you need any more information please let me know |
|||
#828 | invalid | Add drive to smartctl database - PM951 NVMe SAMSUNG 256GB | ||
Description |
Hi, Can I request the following drive get added to the smartctl database please. below is output from smartctl.exe -d ata -s on -q noserial -x /dev/sda smartctl 6.5 2016-05-07 r4318 [i686-w64-mingw32-win10(64)] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: PM951 NVMe SAMSUNG 256GB Firmware Version: BXV77D0Q Device is: Not in smartctl database [for details use: -P showall] ATA Version is: [No Information Found] Local Time is: Mon Apr 03 15:44:56 2017 GMTDT SMART support is: Available - device has SMART capability. Enabled status cached by OS, trying SMART RETURN STATUS cmd. SMART support is: Disabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Unavailable Write cache is: Unavailable ATA Security is: Unavailable Wt Cache Reorder: Unavailable === START OF ENABLE/DISABLE COMMANDS SECTION === SMART Enabled. Read SMART Data failed: Function not implemented === START OF READ SMART DATA SECTION === SMART Status not supported: Function not implemented SMART overall-health self-assessment test result: UNKNOWN! SMART Status, Attributes and Thresholds cannot be read. Read SMART Log Directory failed: Input/output error General Purpose Log Directory not supported SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test Log not supported Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) not supported |
|||
#829 | duplicate | Add drive to smartctl database - PC300 NVMe SK hynix 256GB | ||
Description |
Hi,
smartctl 6.5 2016-05-07 r4318 [i686-w64-mingw32-win10(64)] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org Warning: Limited functionality due to missing admin rights === START OF INFORMATION SECTION === Device Model: PC300 NVMe SK hynix 256GB Firmware Version: 20005A00 Device is: Not in smartctl database [for details use: -P showall] ATA Version is: [No Information Found] Local Time is: Mon Apr 03 15:46:07 2017 GMTDT SMART support is: Available - device has SMART capability. Enabled status cached by OS, trying SMART RETURN STATUS cmd. SMART support is: Disabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Unavailable Write cache is: Unavailable ATA Security is: Unavailable Wt Cache Reorder: Unavailable === START OF ENABLE/DISABLE COMMANDS SECTION === SMART Enabled. Read SMART Data failed: Function not implemented === START OF READ SMART DATA SECTION === SMART Status not supported: Function not implemented SMART overall-health self-assessment test result: UNKNOWN! SMART Status, Attributes and Thresholds cannot be read. Read SMART Log Directory failed: Function requires admin rights General Purpose Log Directory not supported SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test Log not supported Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) not supported |
Note:
See TracQuery
for help on using queries.