Custom Query (1414 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (133 - 135 of 1414)

Ticket Resolution Summary Owner Reporter
#304 fixed Add a memory device reference in drivedb Christian Franke jeremy385892
Description

I would like adding the following memory device reference in drivedb:

START OF INFORMATION SECTION

Device Model: 2GB SATA Flash Drive Serial Number: C0112011122100000073 Firmware Version: SFDDA01C User Capacity: 2,011,226,112 bytes [2.01 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device <b>Device is: Not in smartctl database [for details use: -P showall]</b> ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Fri Oct 25 15:13:02 2013 GMT SMART support is: Available - device has SMART capability. SMART support is: Enabled

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values: Offline data collection status: (0x00) Offline data collection activity

was never started. Auto Offline Data Collection: Disabled.

Total time to complete Offline data collection: ( 30) seconds. Offline data collection capabilities: (0x00) Offline data collection not supported. SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode. Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

No General Purpose Logging support.

SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always -

16777215

2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline -

0

3 Spin_Up_Time 0x0007 100 100 050 Pre-fail Always -

0

5 Reallocated_Sector_Ct 0x0013 100 100 050 Pre-fail Always -

0

7 Unknown_SSD_Attribute 0x000b 100 100 050 Pre-fail Always -

0

8 Unknown_SSD_Attribute 0x0005 100 100 050 Pre-fail Offline -

0

9 Power_On_Hours 0x0012 100 100 000 Old_age Always -

24

10 Unknown_SSD_Attribute 0x0013 100 100 050 Pre-fail Always -

0

12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always -

18

168 Unknown_Attribute 0x0012 100 100 000 Old_age Always -

0

175 Program_Fail_Count_Chip 0x0003 100 100 010 Pre-fail Always -

0

192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always -

0

194 Temperature_Celsius 0x0022 040 100 000 Old_age Always -

40 (Min/Max 30/60)

197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always -

0

240 Unknown_SSD_Attribute 0x0013 100 100 050 Pre-fail Always -

0

160 Unknown_Attribute 0x0000 100 100 010 Old_age Offline -

6

161 Unknown_Attribute 0x0000 100 100 010 Old_age Offline -

6

162 Unknown_Attribute 0x0000 100 100 005 Old_age Offline -

252

163 Unknown_Attribute 0x0000 100 100 001 Old_age Offline -

35

164 Unknown_Attribute 0x0000 100 100 001 Old_age Offline -

10

165 Unknown_Attribute 0x0000 100 100 001 Old_age Offline -

10

241 Total_LBAs_Written 0x0000 100 100 000 Old_age Offline -

4777601

SMART Error Log Version: 0 No Errors Logged

SMART Self-test log structure revision number 0 Warning: ATA Specification requires self-test log structure revision number = 1 No self-tests have been logged. [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported

#1253 duplicate Add database Kingston SEDC500R1920G A S Carneiro
Description

Not in DB

please ADD smartctl-Kingston-SEDC500R1920G.txt

#1610 fixed Add database entry for Crucial MX500 (CT4000MX500SSD1, FW M3CR044) Gabriele Pohl Martin H.
Description

Despite the SSD comes with a newer firmware revision, it still seems to suffer from #1227 (fluctuating Current_Pending_Sector)

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.