Custom Query (1546 matches)
Results (106 - 108 of 1546)
| Ticket | Resolution | Summary | Owner | Reporter |
|---|---|---|---|---|
| #1471 | fixed | Add Raw Format for Seagate Error Rates (ST4000DM004-2CV104) | ||
| Description |
The Seagate Barracuda ST4000DM004-2CV104 I own reports error rates in attributes 1, 7, and 159 in an unusual way: First, the number of errors (16bit), then the number of operations (32 bit). The added patch adds a new RAWFMT, and enables it in the drivesdb for my disk. |
|||
| #636 | fixed | Add SAMSUNG MZ7LN128HCHP-00000 | ||
| Description |
Please add SAMSUNG MZ7LN128HCHP-00000 to the database. It seems to be Samsung PM-871 smartctl 6.5 2016-01-06 r4198 [x86_64-linux-4.4.0-1.el6.elrepo.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG MZ7LN128HCHP-00000
Serial Number: S1ZFNXAG701382
LU WWN Device Id: 5 002538 d402b799b
Firmware Version: EMT0100Q
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Jan 17 17:27:03 2016 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 64) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 49
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 3
170 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0
171 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0
172 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0
173 Unknown_Attribute 0x0033 099 099 005 Pre-fail Always - 1
174 Unknown_Attribute 0x0032 099 099 000 Old_age Always - 1
178 Used_Rsvd_Blk_Cnt_Chip 0x0013 100 100 010 Pre-fail Always - 0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 386
184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0032 063 056 000 Old_age Always - 37
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
233 Media_Wearout_Indicator 0x0013 099 099 000 Pre-fail Always - 16768826
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 123
242 Total_LBAs_Read 0x0032 099 099 000 Old_age Always - 114
249 Unknown_Attribute 0x0032 099 099 000 Old_age Always - 128
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
255 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|||
| #1811 | duplicate | Add SK hynix SE5110 to the Database (Same request as #1776) | ||
| Description |
Hi I wrote #1776 request because I think I need to update the drive database. However, even after 3 months of requesting #1776 cases, there is no update in the drive database, so I'm requesting it again. There are a total of four drives that need to be registered, and I have attached this information as a file, so please register as soon as possible. Thank you. |
|||