Custom Query (1546 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (382 - 384 of 1546)

Ticket Resolution Summary Owner Reporter
#85 fixed Enhance drivedb for SAMSUNG SV1604N Christian Franke tobthea
Description

I have got a SAMSUNG SV1604N with firmware version TR100-23. After some research on the web I found out that I need to manually append -v 9,halfminutes -F samsung2 in order to get a correct output from smartctl. -v 9,halfminutes is needed otherwise Power on Hours is insanely high (~750000 hours) -F samsung2 is needed - otherwise I get an extra warning: "Warning: ATA error count xxx inconsistent with error log pointer 5" Please add this information to your drive db so that everybody will get the correct values by default. Thanks

#1258 duplicate Error Counter logging not supported (SAMSUNG MZILT800HAHQ0D3) AN
Description

smartctl is not reporting disk-level checks and not running self tests. Getting below error:

#smartctl -a -d megaraid,1 /dev/sdb
smartctl 7.0 2018-12-30 r4883  (local build)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Vendor:               SAMSUNG
Product:              MZILT800HAHQ0D3
Revision:             DWF8
Compliance:           SPC-5
User Capacity:        800,166,076,416 bytes [800 GB]
Logical block size:   512 bytes
Physical block size:  4096 bytes
LU is resource provisioned, LBPRZ=1
Rotation Rate:        Solid State Device
Form Factor:          2.5 inches
Device type:          disk
Transport protocol:   SAS (SPL-3)
Local Time is:        Wed Oct 30 04:17:00 2019 PDT
SMART support is:     Available - device has SMART capability.
SMART support is:     Enabled
Temperature Warning:  Enabled

=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK

Current Drive Temperature:     33 C
Drive Trip Temperature:        70 C

Elements in grown defect list: 0

Error Counter logging not supported

Device does not support Self Test logging

i have tried enabling with --smart=on --saveauto=on,-T permissive but nothing works.

#50 fixed Error Recovery Control querrying and setting Christian Franke wmene@…
Description

On November 20, 2009, Richard Gregory submitted a patch to the smartmontools support list to get and set Error Recovery Control parameters http://markmail.org/thread/7hfdczprhkvd3wvp

which he describes on his page here: http://www.csc.liv.ac.uk/~greg/projects/erc/

It would be nice if smartmontools would incorporate this into their official build. As Richard stated, ERC is defined as a sub command of SMART Command Transport.

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.