Custom Query (1455 matches)
Results (289 - 291 of 1455)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#98 | wontfix | Error SMART Status command failed | ||
Description |
Hi, I am having this message using gsmartcontrol. smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net START OF INFORMATION SECTIONModel Family: Seagate Momentus 7200.4 series Device Model: ST9500420ASG Serial Number: 5VJ2QGLW Firmware Version: 0002SDM1 User Capacity: 500,107,862,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Mon Sep 13 10:49:16 2010 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled START OF READ SMART DATA SECTIONError SMART Status command failed Please get assistance from http://smartmontools.sourceforge.net/ Register values returned from SMART Status command are:
SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. |
|||
#100 | wontfix | please make smart module for lm_sensors | ||
Description |
lm_sensors has the ability to display sensor data from multiple sources. Unfortunately there is not a module that will display HD temperature data. Instead the lm_sensors documentation says that the smartmontools package should be used to gather and display this data. While the smart tools are certainly very nice as a separate package, it would be very helpful if the smart data was integrated with lm_sensors so that the HD temperature could be displayed alongside all of the other sensor data. For example there are numerous tools that have been compiled with the sensor libraries (EG, desktop applets, SNMP agents, etc), and it would be very helpful if HD temperature data was available through those channels alongside all of the other sensor readings, instead of isolated from them. I am making the same request to the lm_sensors developers Thanks |
|||
#129 | wontfix | 209480318976 Currently unreadable (pending) sectors | ||
Description |
Hello, I have 4 Samsung drives running in RAID 5 on Centos 5.5, smartctl version 5.38. I get this error every few days for 2 of 4 drives (HD502HJ): "Device: /dev/sdd, 209480318976 Currently unreadable (pending) sectors" (always 209480318976) followed by this: "Device: /dev/sdb, Failed SMART usage Attribute: 197 Current_Pending_Sector." Everything else seems to be OK: # smartctl -a /dev/sdd smartctl version 5.38 [x86_64-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ START OF INFORMATION SECTIONDevice Model: SAMSUNG HD502HJ Serial Number: S20BJ9BZXXXXXX Firmware Version: 1AJ10001 User Capacity: 500,107,862,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: Not recognized. Minor revision code: 0x28 Local Time is: Sat Dec 11 19:51:32 2010 CET ==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details. SMART support is: Available - device has SMART capability. SMART support is: Enabled START OF READ SMART DATA SECTIONSMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity
Self-test execution status: ( 0) The previous self-test routine completed
Total time to complete Offline data collection: (4800) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate.
SMART capabilities: (0x0003) Saves SMART data before entering
Error logging capability: (0x01) Error logging supported.
Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 80) minutes. SCT capabilities: (0x003f) SCT Status supported.
SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
191 G-Sense_Error_Rate 0x0022 252 252 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 064 055 000 Old_age Always - 33 (Lifetime Min/Max 22/45) 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 100 100 000 Old_age Always - 76 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 14 223 Load_Retry_Count 0x0032 252 252 000 Old_age Always - 0 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 5 SMART Error Log Version: 1 ATA Error Count: 76 (device log contains only the most recent five errors)
Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 76 occurred at disk power-on lifetime: 1903 hours (79 days + 7 hours)
Error 75 occurred at disk power-on lifetime: 1899 hours (79 days + 3 hours)
Error 74 occurred at disk power-on lifetime: 1894 hours (78 days + 22 hours)
Error 73 occurred at disk power-on lifetime: 1886 hours (78 days + 14 hours)
Error 72 occurred at disk power-on lifetime: 1866 hours (77 days + 18 hours)
SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 2021 - # 2 Short offline Completed without error 00% 2019 - # 3 Short offline Completed without error 00% 1995 - # 4 Short offline Completed without error 00% 1971 - # 5 Short offline Completed without error 00% 1947 - # 6 Short offline Completed without error 00% 1922 - # 7 Short offline Completed without error 00% 1899 - # 8 Short offline Completed without error 00% 1875 - # 9 Extended offline Completed without error 00% 1854 - #10 Short offline Completed without error 00% 1851 - #11 Short offline Completed without error 00% 1827 - #12 Short offline Completed without error 00% 1803 - #13 Short offline Completed without error 00% 1779 - #14 Short offline Completed without error 00% 1755 - #15 Short offline Completed without error 00% 1731 - #16 Short offline Completed without error 00% 1707 - #17 Extended offline Completed without error 00% 1686 - #18 Short offline Completed without error 00% 1684 - #19 Short offline Completed without error 00% 1660 - #20 Short offline Completed without error 00% 1636 - #21 Short offline Completed without error 00% 1612 - SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1 SMART Selective self-test log data structure revision number 0 Warning: ATA Specification requires selective self-test log data structure revision number = 1
Selective self-test flags (0x0):