Custom Query (1363 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (172 - 174 of 1363)

Ticket Resolution Summary Owner Reporter
#1166 duplicate not in drivedb.h: SanDisk Ultra 3D (SanDisk SDSSDH3500G) GurkenPapst
#1169 duplicate Drive Support - WDC WDS200T2B0A-00SM50 BCCHR Support
Description

I can see the following drive isn't yet in the smartctl database for smartctl 7.0 2018-12-30 r4883. I've included output below.

[root@host:/root/smartmontools-7.0]# smartctl -d megaraid,20 /dev/sda -a
smartctl 7.0 2018-12-30 r4883 [x86_64-linux-3.10.0-693.21.1.el7.x86_64] (local build)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WDC WDS200T2B0A-00SM50
Serial Number:    174901800006
LU WWN Device Id: 5 001b44 8b6844df6
Firmware Version: X61130WD
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is:  SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Thu Mar  7 10:17:53 2019 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: ATA return descriptor not supported by controller firmware
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x11) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.

SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0032   100   100   ---    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   ---    Old_age   Always       -       8754
 12 Power_Cycle_Count       0x0032   100   100   ---    Old_age   Always       -       35
165 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       77005621
166 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       1
167 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       39
168 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       49
169 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       1237
170 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
173 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       18
174 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       22
184 End-to-End_Error        0x0032   100   100   ---    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   ---    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   ---    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   076   037   ---    Old_age   Always       -       24 (Min/Max 18/37)
199 UDMA_CRC_Error_Count    0x0032   100   100   ---    Old_age   Always       -       0
230 Unknown_SSD_Attribute   0x0032   100   100   ---    Old_age   Always       -       1374411555152
232 Available_Reservd_Space 0x0033   100   100   004    Pre-fail  Always       -       100
233 Media_Wearout_Indicator 0x0032   100   100   ---    Old_age   Always       -       37803
234 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       39878
241 Total_LBAs_Written      0x0030   253   253   ---    Old_age   Offline      -       21669
242 Total_LBAs_Read         0x0030   253   253   ---    Old_age   Offline      -       253116
244 Unknown_Attribute       0x0032   000   100   ---    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported
#1173 duplicate Database addition: SanDisk SDSSDH3500G Randy Wright
Description

I recently purchased a new 500GB SanDisk SSD, model SDSSDH3500G, which is not in the database.

I created a local smart_drivedb.h adding it with the attributes of the other products found under "Marvell based SanDisk SSDs" and that appears to work find.

This was verified on Debian Stretch, both with the version installed by Debian as well as a build of the latest smartmontools source cloned from the github repo.