#1017 | duplicate | make smartd usable as temperature monitor / replace hddtemp | ||
Description |
Hi. It seems to me that hddtemp, is more or less dead and unmaintained... and since (AFAIK) its temperature reading is also based on SMART, there is not much sense in having both, smartd and hddtemp. For many of my newer devices like SSDs, hddtemp reports "no temp sensor found" or so... while smartmontools work perfectly on them (and display temperature). smartd already seems to have some limited functionality to monitor a device's temperature, namely via: -W DIFF[,INFO[,CRIT]] There are a number of problems with it: 1) Most importantly, it seems that warnings are not re-sent as they occur (but only once a day?). For example, I have had a line in smartd.conf like: /dev/disk/by-id/ata-Samsung_SSD_850_PRO_1TB_S252NXAG910017F -d auto -d removable -n standby,4 -a -W 0,50,55 -m root -M exec /usr/share/smartmo ntools/smartd-runner For testing purposes I changed that to -W 0,20,25 and got an alert. Changed it back to -W 0,50,55 (which is fine for that device) and restarted... and then I repeated this (i.e. going back to something that should trigger a warning). However, no further warning. This behaviour may be reasonable for other smart values, e.g. things like:
would typically get only worse and not better again. And things like:
may increase pretty fast on some devices (one such value does on Seagate) and it's perfectly fine for them. But for temperature monitoring it's IMHO bad: My Samsung SSD for example, supports I think up to 70°C. So I'd like to get a warning at say 50°C ... but not only the first time per day, because the temperature may decrease again then (or I just decrease the IO load on the device)... only to rise again shortly after (which I wouldn't notice anymore, as no further warning is sent). Especially on mobile devices like laptops, temperatures can easily go up and down quite regularly. Therefore it makes sense to send temperature errors every time they occur (i.e. that is once per check interval). 2) devices typically also have a minimum operation temperature This is typically pretty low, so I'm not sure if it's can be even monitored properly (=> do the temp sensors of the disks give reasonable values for such low temps?)... but if they can, it would be nice if smartd would also monitor for a minimum temperature. 3) smartmontools should know the max[/min] temperatures of the devices *if* smartd would become a replacement / alternative to hddtemp, it would of course be nice if it comes with a database of max[/min] temperatures for known devices. Example, my Samsung SSD (according to Samsung) operate in some range between 0-70°C. My HDDs take much less (~50°C or so? would need to look it up). So it would be nice, if there'd be a DB, that automatically selects reasonable values, like for the SSD in my case: INFO at 60°C, CRIT at 70°C Cheers, Chris. |
|||
#1022 | duplicate | Micron_5200_MTFDDAK1T9TDC | ||
Description |
https://www.micron.com/products/solid-state-storage/product-lines/5200 https://www.micron.com/~/media/documents/products/data-sheet/ssd/5200_ssd.pdf smartctl 6.2 2017-02-27 r4394 [x86_64-linux-3.10.0-514.6.1.el7.x86_64] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Micron_5200_MTFDDAK1T9TDC Serial Number: 17501A67E9AE LU WWN Device Id: 5 00a075 11a67e9ae Firmware Version: D1MU003 User Capacity: 1 920 383 410 176 bytes [1,92 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 (unknown minor revision code: 0x006d) SATA Version is: SATA >3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Wed Apr 4 06:51:15 2018 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 3331) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 14) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0 5 Reallocated_Sector_Ct -O--CK 100 100 001 - 0 9 Power_On_Hours -O--CK 100 100 000 - 177 12 Power_Cycle_Count -O--CK 100 100 001 - 1 170 Unknown_Attribute PO--CK 100 100 010 - 0 171 Unknown_Attribute -O--CK 100 100 000 - 0 172 Unknown_Attribute -O--CK 100 100 001 - 0 173 Unknown_Attribute -O--CK 100 100 000 - 3 174 Unknown_Attribute -O--CK 100 100 000 - 0 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error -O--CK 100 100 000 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 100 000 - 0 194 Temperature_Celsius -O---K 074 071 000 - 26 (Min/Max 19/29) 195 Hardware_ECC_Recovered -O--CK 100 100 000 - 0 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O--CK 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0 202 Unknown_SSD_Attribute ----CK 100 100 001 - 0 206 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0 246 Unknown_Attribute -O--CK 100 100 000 - 10332552282 247 Unknown_Attribute -O--CK 100 100 000 - 323353157 248 Unknown_Attribute -O--CK 100 100 000 - 210327612 180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 000 000 000 - 6718 210 Unknown_Attribute -O--CK 100 100 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 51 Comprehensive SMART error log 0x03 GPL R/O 16383 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x24 GPL R/O 8000 Current Device Internal Status Data log 0x25 GPL R/O 8000 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0 GPL VS 35328 Device vendor specific log 0xa1 GPL,SL VS 4 Device vendor specific log 0xa3 GPL VS 13824 Device vendor specific log 0xa4 GPL VS 354 Device vendor specific log 0xa4 SL VS 98 Device vendor specific log 0xa5 GPL VS 8000 Device vendor specific log 0xa5 SL VS 64 Device vendor specific log 0xa6 GPL VS 8000 Device vendor specific log 0xa6 SL VS 64 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log size 16383 not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 147 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Completed [00% left] (37752960-37818495) 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) SCT Support Level: 0 Device State: Active (0) Current Temperature: 26 Celsius Power Cycle Min/Max Temperature: 19/29 Celsius Lifetime Min/Max Temperature: 19/29 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: -5/75 Celsius Temperature History Size (Index): 478 (19) Index Estimated Time Temperature Celsius 20 2018-04-03 22:54 ? - ... ..(459 skipped). .. - 2 2018-04-04 06:34 ? - 3 2018-04-04 06:35 22 *** 4 2018-04-04 06:36 23 **** 5 2018-04-04 06:37 24 ***** 6 2018-04-04 06:38 24 ***** 7 2018-04-04 06:39 24 ***** 8 2018-04-04 06:40 27 ******** 9 2018-04-04 06:41 23 **** 10 2018-04-04 06:42 24 ***** 11 2018-04-04 06:43 23 **** 12 2018-04-04 06:44 23 **** 13 2018-04-04 06:45 24 ***** ... ..( 4 skipped). .. ***** 18 2018-04-04 06:50 24 ***** 19 2018-04-04 06:51 26 ******* SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Description 1 ===== = = == General Statistics (rev 1) == 1 0x008 4 1 Lifetime Power-On Resets 1 0x010 4 177 Power-on Hours 1 0x018 6 10332552450 Logical Sectors Written 1 0x020 6 89403698 Number of Write Commands 1 0x028 6 838048722 Logical Sectors Read 1 0x030 6 3394844 Number of Read Commands 1 0x038 6 639840000 Date and Time TimeStamp 4 ===== = = == General Errors Statistics (rev 1) == 4 0x008 4 0 Number of Reported Uncorrectable Errors 4 0x010 4 0 Resets Between Cmd Acceptance and Completion 5 ===== = = == Temperature Statistics (rev 1) == 5 0x008 1 26 Current Temperature 5 0x010 1 - Average Short Term Temperature 5 0x018 1 - Average Long Term Temperature 5 0x020 1 29 Highest Temperature 5 0x028 1 19 Lowest Temperature 5 0x030 1 - Highest Average Short Term Temperature 5 0x038 1 - Lowest Average Short Term Temperature 5 0x040 1 - Highest Average Long Term Temperature 5 0x048 1 - Lowest Average Long Term Temperature 5 0x050 4 0 Time in Over-Temperature 5 0x058 1 70 Specified Maximum Operating Temperature 5 0x060 4 0 Time in Under-Temperature 5 0x068 1 0 Specified Minimum Operating Temperature 6 ===== = = == Transport Statistics (rev 1) == 6 0x008 4 0 Number of Hardware Resets 6 0x010 4 0 Number of ASR Events 6 0x018 4 0 Number of Interface CRC Errors 7 ===== = = == Solid State Device Statistics (rev 1) == 7 0x008 1 0~ Percentage Used Endurance Indicator |_ ~ normalized value SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0003 4 0 R_ERR response for device-to-host data FIS 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0006 4 0 R_ERR response for device-to-host non-data FIS 0x000a 4 0 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS |
|||
#1024 | duplicate | Crucial CT250MX500SSD1 | ||
Description |
Details for Crucial MX500 (240GB), not found in the trunk drivedb.h. Product page: http://uk.crucial.com/gbr/en/ct250mx500ssd1 Attaching report from the device for addition into the database. |