Custom Query (1566 matches)
Results (448 - 450 of 1566)
| Ticket | Resolution | Summary | Owner | Reporter |
|---|---|---|---|---|
| #776 | invalid | Self-test log differences between "-a" and "-x" options | ||
| Description |
Hi, My SSD provide a different self-test log output when using "-x" option instead "-a": with "-a" smartctl said that device doesn't support this feature, instead with "-x" the self-test log appear, but with several running tests and mixed lifetime hours. Attached you can find the two outputs (generated also with -r ataioctl,2 option) of device. Let me know if more data is needed. Greetings, Sam |
|||
| #781 | invalid | smartctl for OCZ-AGILITY3 incorrectly reporting temperature of 128C | ||
| Description |
When running smartctl in FreeNAS 10 on an OCZ-AGILITY3 drive, I get a Temperature_Celsius reading of 128. The other drives in my system (Western Digital Reds) report values between 25-27C. [root@freenas] ~# smartctl -a /dev/ada4
smartctl 6.4 2015-06-04 r4109 [FreeBSD 10.3-STABLE amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: OCZ-AGILITY3
Serial Number: OCZ-XXXXXXXXXXXXXXXX
LU WWN Device Id: 5 e83a97 f1fb643ef
Firmware Version: 2.15
User Capacity: 60,022,480,896 bytes [60.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Dec 15 17:11:44 2016 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2097) seconds.
Offline data collection
capabilities: (0x7f) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 088 088 050 Pre-fail Always - 0/40025267
5 Retired_Block_Count 0x0033 100 100 003 Pre-fail Always - 0
9 Power_On_Hours_and_Msec 0x0032 098 098 000 Old_age Always - 2522h+33m+58.310s
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 640
171 Program_Fail_Count 0x0032 000 000 000 Old_age Always - 0
172 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0
174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 15
177 Wear_Range_Delta 0x0000 000 000 000 Old_age Offline - 3
181 Program_Fail_Count 0x0032 000 000 000 Old_age Always - 0
182 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 128 129 000 Old_age Always - 128 (0 127 0 129 0)
195 ECC_Uncorr_Error_Count 0x001c 120 120 000 Old_age Offline - 0/40025267
196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0
201 Unc_Soft_Read_Err_Rate 0x001c 120 120 000 Old_age Offline - 0/40025267
204 Soft_ECC_Correct_Rate 0x001c 120 120 000 Old_age Offline - 0/40025267
230 Life_Curve_Status 0x0013 100 100 000 Pre-fail Always - 100
231 SSD_Life_Left 0x0013 100 100 010 Pre-fail Always - 0
233 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 2000
234 SandForce_Internal 0x0032 000 000 000 Old_age Always - 2733
241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 2733
242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 4477
SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
I can include an actual Serial Number if that's necessary. If you care to view the ticket I originally filed with FreeNAS 10, it's included here. |
|||
| #793 | invalid | SMART error (FailedReadSmartSelfTestLog) detected on host: xxx | ||
| Description |
Hi, I need your help regarding an issue related with smartmontools apps. I have a linux server (Debian GNU/Linux 8 (jessie), installed on a Supermicro 2U 6027R-E1R12L with a raid controller LSI. root@pm03:~# lspci | egrep -i 'raid|adaptec' 03:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05) On LSI I have 2 raid configuration:
root@pm03:~#_ smartctl --scan /dev/sda_ -d scsi # /dev/sda, SCSI device /dev/sdb_ -d scsi # /dev/sdb, SCSI device /dev/bus/0_ -d megaraid,0 # /dev/bus/0 [megaraid_disk_00], SCSI device /dev/bus/0_ -d megaraid,1 # /dev/bus/0 [megaraid_disk_01], SCSI device /dev/bus/0_ -d megaraid,2 # /dev/bus/0 [megaraid_disk_02], SCSI device /dev/bus/0_ -d megaraid,3 # /dev/bus/0 [megaraid_disk_03], SCSI device /dev/bus/0_ -d megaraid,4 # /dev/bus/0 [megaraid_disk_04], SCSI device /dev/bus/0__ -d megaraid,5 # /dev/bus/0 [megaraid_disk_05], SCSI device /dev/bus/0_ -d megaraid,6 # /dev/bus/0 [megaraid_disk_06], SCSI device /dev/bus/0_ -d megaraid,7 # /dev/bus/0 [megaraid_disk_07], SCSI device /dev/bus/0 -d megaraid,15 # /dev/bus/0 [megaraid_disk_15], SCSI device spare issue - I have received an error log "SMART error (FailedReadSmartSelfTestLog) detected on host: xxx" (see the message logs).
This message was generated by the smartd daemon running on: host name: XXXX DNS domain: mydomain.int The following warning/error was logged by the smartd daemon: Device: /dev/bus/0 [megaraid_disk_08], Read SMART Self-Test Log Failed Device_ info: [SEAGATE ST2000NM0023 0004], lu id: 0x5000c500628f5dcf, S/N: Z1Y2C8G90000C5124838, 2.00 TB For details see host's SYSLOG. You can also use the smartctl utility for further investigation. Another message will be sent in 24 hours if the problem persists._
This message was generated by the smartd daemon running on: host name: pm03 DNS domain: mercury.int The following warning/error was logged by the smartd daemon: Device: /dev/bus/0 [megaraid_disk_15], Read SMART Self-Test Log Failed Device info: [SEAGATE ST2000NM0023 0004], lu id: 0x5000c500845a1abf, S/N: Z1X5VF2R0000C6095M9C, 2.00 TB For details see host's SYSLOG. You can also use the smartctl utility for further investigation. Another message will be sent in 24 hours if the problem persists. Another problem that I noticed after I have detect is that I cannot see in -- Disk information -- about the spare disk, using the command megaclisas-status && megasasctl
before
https://drive.google.com/open?id=0B5sUwIIchHUgUlA4UGwyZTZaSjQ
after
https://drive.google.com/open?id=0B5sUwIIchHUgMXBDRzExaXhZOE0
root@pm03:~# smartctl -a /dev/bus/0 -d megaraid,15 smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.4.35-1-pve] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: SEAGATE Product: ST2000NM0023 Revision: 0004 Compliance: SPC-4 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Logical block size: 512 bytes LU is fully provisioned Rotation Rate: 7200 rpm Form Factor: 3.5 inches Logical Unit id: 0x5000c500845a1abf Serial number: Z1X5VF2R0000C6095M9C Device type: disk Transport protocol: SAS (SPL-3) Local Time is: Fri Jan 13 13:54:06 2017 EET SMART support is: Unavailable - device lacks SMART capability. === START OF READ SMART DATA SECTION === Current Drive Temperature: 0 C Drive Trip Temperature: 0 C Error Counter logging not supported Device does not support Self Test logging megacli 8.07.14-1 amd64 LSI Logic MegaRAID SAS MegaCLI megaclisas-status 0.15 all get RAID status out of LSI MegaRAID SAS HW RAID controllers megactl 0.4.1+svn20090725.r6-5 amd64 LSI MegaRAID SCSI/SAS reporting tool megaraid-status 0.12 all get RAID status out of LSI MegaRAID SCSI/SAS HW RAID controllers Thanks |
|||