Custom Query (1566 matches)
Results (424 - 426 of 1566)
| Ticket | Resolution | Summary | Owner | Reporter |
|---|---|---|---|---|
| #507 | invalid | Strange attributes on Seagate Constellation ES.3 | ||
| Description |
We normally monitor SMART attribute 5 Reallocated_Sector_Ct to predict drive failure. Recently we received a shipment of replacement drives (Seagate Constellation ES.3) that don't appear to have SMART attributes in any version of smartctl, up to and including SVN from 12/18/14. Is it just that support for these drives hasn't yet been added to smartmontools, or is there something new/peculiar about these drives? Info: # ./smartctl -i /dev/sdae smartctl 6.4 2014-12-13 r4030 [x86_64-linux-3.13.0-43-generic] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: SEAGATE Product: ST4000NM0023 Revision: 0004 Compliance: SPC-4 User Capacity: 4,000,787,030,016 bytes [4.00 TB] Logical block size: 512 bytes LB provisioning type: unreported, LBPME=0, LBPRZ=0 Rotation Rate: 7200 rpm Form Factor: 3.5 inches Logical Unit id: 0x5000c500626b0313 Serial number: Z1Z5PQ6Z0000C509C0UY Device type: disk Transport protocol: SAS (SPL-3) Local Time is: Thu Dec 18 16:04:45 2014 CST SMART support is: Available - device has SMART capability. SMART support is: Enabled Temperature Warning: Enabled # ./smartctl --attributes /dev/sdae smartctl 6.4 2014-12-13 r4030 [x86_64-linux-3.13.0-43-generic] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF READ SMART DATA SECTION === Current Drive Temperature: 33 C Drive Trip Temperature: 60 C Manufactured in week 37 of year 2014 Specified cycle count over device lifetime: 10000 Accumulated start-stop cycles: 96 Specified load-unload count over device lifetime: 300000 Accumulated load-unload cycles: 127 Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 2968316052 Blocks received from initiator = 3752175265 Blocks read from cache and sent to initiator = 2227814356 Number of read and write commands whose size <= segment size = 13010546 Number of read and write commands whose size > segment size = 759449 Vendor (Seagate/Hitachi) factory information number of hours powered up = 887.18 number of minutes until next internal SMART test = 0 |
|||
| #514 | invalid | smartcrl question | ||
| Description |
Hi, I'm a SSD Manufacturer,If we want provide user that our products can support smartcrl under the linux OS. How can I do? Do you have any certificates we can join? |
|||
| #518 | invalid | Is following "FIRMWARE IMPENDING FAILURE*" errors critical ? | ||
| Description |
Is following errors critical:? FIRMWARE IMPENDING FAILURE GENERAL HARD DRIVE FAILURE FIRMWARE IMPENDING FAILURE DRIVE ERROR RATE TOO HIGH FIRMWARE IMPENDING FAILURE DATA ERROR RATE TOO HIGH FIRMWARE IMPENDING FAILURE SEEK ERROR RATE TOO HIGH FIRMWARE IMPENDING FAILURE TOO MANY BLOCK REASSIGNS FIRMWARE IMPENDING FAILURE ACCESS TIMES TOO HIGH FIRMWARE IMPENDING FAILURE START UNIT TIMES TOO HIGH FIRMWARE IMPENDING FAILURE CHANNEL PARAMETRICS FIRMWARE IMPENDING FAILURE CONTROLLER DETECTED FIRMWARE IMPENDING FAILURE THROUGHPUT PERFORMANCE FIRMWARE IMPENDING FAILURE SEEK TIME PERFORMANCE FIRMWARE IMPENDING FAILURE SPIN-UP RETRY COUNT FIRMWARE IMPENDING FAILURE DRIVE CALIBRATION RETRY COUNT If an error above occurs(smartd reports it) should I replace HDD ? Or it is not possible to say it exactly and need to analyze more with special tools. I have OS Linux x86_64-linux-3.0.101(SUSE). Vendor HDD: TOSHIBA |
|||