#744 | fixed | New variant of Sandisk Ultra II | ||
Description |
Newer Sandisk Ultra II drives are using new identification and therefore smartmontools is not able to correctly detect the drive. Here is the output of my Sandisk Ultra II 960GB: $ sudo smartctl -x /dev/sda smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.7.4-040704-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SanDisk Ultra II 960GB Serial Number: 160965442183 LU WWN Device Id: 5 001b44 4a495cf0c Firmware Version: X41100RL User Capacity: 960,197,124,096 bytes [960 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Sep 23 22:15:39 2016 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SMART Attributes Data Structure revision number: 4 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct -O--CK 100 100 --- - 0 9 Power_On_Hours -O--CK 100 100 --- - 1041 12 Power_Cycle_Count -O--CK 100 100 --- - 257 165 Unknown_Attribute -O--CK 100 100 --- - 4849710 166 Unknown_Attribute -O--CK 100 100 --- - 0 167 Unknown_Attribute -O--CK 100 100 --- - 69 168 Unknown_Attribute -O--CK 100 100 --- - 1 169 Unknown_Attribute -O--CK 100 100 --- - 1261 170 Unknown_Attribute -O--CK 100 100 --- - 0 171 Unknown_Attribute -O--CK 100 100 --- - 0 172 Unknown_Attribute -O--CK 100 100 --- - 0 173 Unknown_Attribute -O--CK 100 100 --- - 0 174 Unknown_Attribute -O--CK 100 100 --- - 15 184 End-to-End_Error -O--CK 100 100 --- - 0 187 Reported_Uncorrect -O--CK 100 100 --- - 0 188 Command_Timeout -O--CK 100 100 --- - 0 194 Temperature_Celsius -O---K 065 045 --- - 35 (Min/Max 23/45) 199 UDMA_CRC_Error_Count -O--CK 100 100 --- - 0 230 Unknown_SSD_Attribute -O--CK 100 100 --- - 55834574861 232 Available_Reservd_Space PO--CK 100 100 004 - 100 233 Media_Wearout_Indicator -O--CK 100 100 --- - 868 234 Unknown_Attribute -O--CK 100 100 --- - 963 241 Total_LBAs_Written ----CK 253 253 --- - 923 242 Total_LBAs_Read ----CK 253 253 --- - 357 244 Unknown_Attribute -O--CK 000 100 --- - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xde GPL VS 8 Device vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1018 - # 2 Short offline Completed without error 00% 987 - # 3 Short offline Aborted by host 00% 766 - Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 257 --- Lifetime Power-On Resets 0x01 0x018 6 4538994804 --- Logical Sectors Written 0x01 0x020 6 1528255 --- Number of Write Commands 0x01 0x028 6 124120818 --- Logical Sectors Read 0x01 0x030 6 494385 --- Number of Read Commands 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x000a 4 3 Device-to-host register FISes sent due to a COMRESET It looks like newer revision of Ultra II drives are just using "SanDisk Ultra II (120|240|480|960)GB" for their identification: see the line 209 of http://pastebin.com/uqF61Bgq and https://bugs.freedesktop.org/attachment.cgi?id=125721 |
|||
#745 | fixed | Add Samsung PM871a | ||
Description |
It's not in our database. It's a successor to the PM871. smartctl 6.6 2016-09-25 r4345 [x86_64-linux-3.10.0-327.36.1.el7.x86_64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SAMSUNG MZ7LN256HMJP-00000 Serial Number: S2MJNX0H403606 LU WWN Device Id: 5 002538 d40cd8db4 Firmware Version: MAV0100Q User Capacity: 256,060,514,304 bytes [256 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Sep 26 23:28:59 2016 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 133) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 1450 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 3 170 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0 171 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0 172 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0 173 Unknown_Attribute 0x0033 099 099 005 Pre-fail Always - 1 174 Unknown_Attribute 0x0032 099 099 000 Old_age Always - 1 178 Used_Rsvd_Blk_Cnt_Chip 0x0013 100 100 010 Pre-fail Always - 0 180 Unused_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 820 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0032 065 064 000 Old_age Always - 35 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 233 Media_Wearout_Indicator 0x0013 099 099 000 Pre-fail Always - 16763233 241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 355 242 Total_LBAs_Read 0x0032 099 099 000 Old_age Always - 3 249 Unknown_Attribute 0x0032 099 099 000 Old_age Always - 355 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 3 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 255 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. |
|||
#746 | fixed | Invalid SMART STATUS output values on FreeNAS | ||
Description |
I have SanDisk SSD drive from Plus series connected in my FreeNAS box. That's what I'm getting from freenas# smartctl -a /dev/ada0 smartctl 6.5 2016-05-07 r4318 [FreeBSD 10.3-STABLE amd64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SandForce Driven SSDs Device Model: SanDisk SDSSDA120G Serial Number: 160696404971 LU WWN Device Id: 5 001b44 4a46cb55b Firmware Version: U21010RL User Capacity: 120,034,123,776 bytes [120 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Wed Oct 5 20:34:04 2016 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === Error SMART Status command failed Please get assistance from http://www.smartmontools.org/ Register values returned from SMART Status command are: CMD=0xb0 FR =0xda NS =0xffff SC =0xff CL =0xff CH =0xff RETURN =0x0000 SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. No failed Attributes found. General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x71) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_ FAILED RAW_VALUE 5 Retired_Block_Count 0x0032 100 100 000 Old_age Always - 0 9 Power_On_Hours_and_Msec 0x0032 179 100 000 Old_age Always - 1203h+00m+00.000s 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 10 166 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 1 167 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 168 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 2 169 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 27 170 Reserve_Block_Count 0x0032 100 100 000 Old_age Always - 0 171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0 173 Unknown_SandForce_Attr 0x0032 100 100 --- Old_age Always - 0 174 Unexpect_Power_Loss_Ct 0x0032 100 100 000 Old_age Always - 3 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 067 100 000 Old_age Always - 33 (Min/Max 0/51) 199 SATA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0 230 Life_Curve_Status 0x0032 100 100 000 Old_age Always - 0 232 Available_Reservd_Space 0x0033 100 100 004 Pre-fail Always - 100 233 SandForce_Internal 0x0032 100 100 000 Old_age Always - 125 241 Lifetime_Writes_GiB 0x0030 253 253 000 Old_age Offline - 110 242 Lifetime_Reads_GiB 0x0030 253 253 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA _of_first_error # 1 Short offline Completed without error 00% 173 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. freenas# smartctl --version smartctl 6.5 2016-05-07 r4318 [FreeBSD 10.3-STABLE amd64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org smartctl comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to redistribute it under the terms of the GNU General Public License; either version 2, or (at your option) any later version. See http://www.gnu.org for further details. smartmontools release 6.5 dated 2016-05-07 at 11:17:46 UTC smartmontools SVN rev 4318 dated 2016-05-07 at 11:18:20 smartmontools build host: amd64-portbld-freebsd10.3 smartmontools build with: C++98, GCC 4.2.1 Compatible FreeBSD Clang 3.4.1 (tags/RELEASE_34/dot1-final 208032) smartmontools configure arguments: '--disable-dependency-tracking' '--enable-sample' '--with-initscriptdir=/usr/local/etc/rc.d' '--prefix=/usr/local' '--localstatedir=/var' '--mandir=/usr/local/man' '--infodir=/usr/local/info/' '--build=amd64-portbld-freebsd10.3' 'build_alias=amd64-portbld-freebsd10.3' 'CXX=c++' 'CXXFLAGS=-O2 -pipe -fstack-protector -fno-strict-aliasing ' 'LDFLAGS= -fstack-protector' 'LIBS=' 'CPPFLAGS=' 'CC=cc' 'CFLAGS=-O2 -pipe -fstack-protector -fno-strict-aliasing' The problematic part of the report above is: Register values returned from SMART Status command are: CMD=0xb0 FR =0xda NS =0xffff SC =0xff CL =0xff CH =0xff RETURN =0x0000 Samsung says they don't see any problem with the drive. Their own SMART checker doesn't reports any problem either. It has to be something with how the drive reacts to the sequence of commands. The drive is connected to the motherboard through the SATA extension card Lycom PE-115 SATA 3 2 Port 6Gbps Low Profile PCI-e 2.0 Host Adapter... can this be related as I've seen problem with this brand related to USB things? This text: SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. causes my FreeNAS installation to panic and spam me with tons of alarms every day. I'd like to see it solved. |