Custom Query (1417 matches)
Results (298 - 300 of 1417)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#712 | fixed | Not in smartctl database: SanDisk Z400s (SanDisk SD8SFAT128G1122) | ||
Description |
SanDisk Z400s: https://www.sandisk.com/business/computing/z400s |
|||
#713 | fixed | Add Innodisk Mini PCIeDOM 1ME3 to the drive database | ||
Description |
smartctl 6.5 2016-05-07 r4318 [ppc-linux-3.2.78-rt113] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Mini PCIeDOM 1ME3 Serial Number: 20151006AA1858000001 LU WWN Device Id: 5 24693e 2015a0001 Firmware Version: S15604 User Capacity: 64,023,257,088 bytes [64.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 3.0, 1.5 Gb/s (current: 1.5 Gb/s) Local Time is: Mon Jan 3 19:25:53 2000 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Read SCT Status failed: scsi error aborted command Wt Cache Reorder: Unknown (SCT Feature Control command failed) === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Total time to complete Offline data collection: ( 32) seconds. Offline data collection capabilities: (0x0b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. No Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x00) Error logging NOT supported. General Purpose Logging supported. SCT capabilities: (0x0039) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate ------ 000 000 000 - 0 2 Throughput_Performance ------ 000 000 000 - 0 3 Spin_Up_Time ------ 000 000 000 - 0 5 Reallocated_Sector_Ct -O---- 100 100 000 - 0 7 Unknown_SSD_Attribute ------ 000 000 000 - 0 8 Unknown_SSD_Attribute ------ 000 000 000 - 0 9 Power_On_Hours -O---- 100 100 000 - 18 10 Unknown_SSD_Attribute ------ 000 000 000 - 0 12 Power_Cycle_Count -O---- 100 100 000 - 33 168 Unknown_Attribute ------ 000 000 000 - 0 169 Unknown_Attribute ------ 099 000 000 - 108851651149824 175 Program_Fail_Count_Chip ------ 000 000 000 - 0 192 Power-Off_Retract_Count ------ 000 000 000 - 0 194 Temperature_Celsius ------ 030 100 000 - 0 (2 100 0 0 0) 197 Current_Pending_Sector ------ 000 000 000 - 0 240 Unknown_SSD_Attribute ------ 000 182 000 - 335698 225 Unknown_SSD_Attribute ------ 000 000 000 - 0 170 Unknown_Attribute PO---- 000 000 --- - 2228224 173 Unknown_Attribute -O--C- 000 000 --- - 196609 229 Unknown_Attribute -O---- 000 000 --- - 88470212370072 236 Unknown_Attribute -O---- 000 000 --- - 0 235 Unknown_Attribute -O---- 000 000 --- - 0 176 Erase_Fail_Count_Chip ------ 000 000 --- - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning Read SMART Log Directory failed: scsi error aborted command ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error aborted command Read GP Log Directory failed SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test Log not supported Selective Self-tests/Logging not supported Read SCT Status failed: scsi error aborted command Read SCT Status failed: scsi error aborted command SCT (Get) Error Recovery Control command failed Device Statistics (GP/SMART Log 0x04) not supported ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: scsi error aborted command Read SATA Phy Event Counters failed |
|||
#714 | fixed | New device: TOSHIBA THNSFJ256GCSU | ||
Description |
My Lenovo notebook has an SSD that is not yet in your database. The report is attached |
Note:
See TracQuery
for help on using queries.